AirGladiator (AGLDTR6) Filter
Installation Instructions
NOTE
When reinstalling or replacing the 41AF Filter Cartridge, tighten
by hand in a crossing (star) bolt pattern. Then, secure the bolts by
torquing each bolt to a minimum of 20 lbf-ft using the same crossing
(star) pattern.
www.bullard.com
©2022 Bullard. All rights reserved.
Teflon is a registered trademark
of E.I. DuPont de Nemours Co.
Bullard Center
2421 Fortune Drive
Lexington, KY 40509 • USA
877-BULLARD (285-5273)
Tel: +1-859-234-6616
Fax: +1-859-246-0243
Americas Operations
1898 Safety Way
Cynthiana, KY 41031 • USA
877-BULLARD (285-5273)
Tel: +1-859-234-6616
Fax: +1-859-234-8987
Bullard GmbH
Dieselstrasse 8a
53424 Remagen • Germany
Tel: +49-2642 999980
Fax: +49-2642 9999829
Bullard Asia-Pacific Pte. Ltd.
LHK Building
701, Sims Drive, #04-03
Singapore 387383
Tel: +65-6745-0556
Fax: +65-6745-5176
60810012674A (0222)
Bullard AirGladiator Filters can be used in conjunction with other compressor safeguards to
supply cleaner air to airline respirators. They can also be used to supply drier, cleaner air to
pneumatic tools and systems. The Bullard AirGladiator Filters can be used to remove
water, oil, odors and organic vapors so that cleaner air is delivered to workers or equipment.
�
WARNING
The AirGladiator filters do not remove carbon monoxide and other toxic gases. Review
and observe all pertinent federal and state safety regulations in conjunction with airline
respirators. Failure to observe safety regulations or improper use of Bullard Airline
Filters could result in death or serious injury.
Set-Up of AirGladiator Filter:
1. Location:
Select a flat, stable location to mount the filter. Bolt the filter in position using
the mounting base. For wall mount applications, the filter carrying handle is designed
for mounting the filter to a wall or steel beam.
2. Assembly
Two (2) separate sub-assembly parts have been shipped with the filter. Each sub-
assembly needs to be installed onto the filter in order to complete the AirGladiator Filter
Assembly before it is connected to the Compressed Air Supply Piping.
•
Dupont
TM
Teflon
®
tape or thread sealant can be used to ensure tight-fitting
connections (No Air Leakage) before installation of all these sub-assemby parts.)
• Inlet Air - Pressure Regulator has an 1” NPT Male Connector which must be threaded
into the AirGladiator Filter’s 1” NPT Female Connector.
• Pressure Gauge for Outlet Air has an 1/4” NPT Male Back Connector which must
be threaded into the 1/4” NPT Female Connector on the Top Flange of the Filter
Outlet Air Connection Area.
• Additional Quick Disconnect Couplings have been shipped with this AirGladiator
Filter. These extra Couplings allow the user to install a maximum of Six (6) Quick
Disconnect Couplings around the Top Flange of the Filter.
3. Connection
Connect compressor hose or piping to Inlet Air - Pressure Regulator (3/4” NPT Female).
Connect the respirator system or pneumatic tool airline hose to the Quick Disconnect
Coupling on the Outlet Air Top Flange. Tighten all piping connections to prevent air leaks
and/or air pressure loss.
�
WARNING
When using a respirator, do not connect the filter to any air source unless you are
certain it supplies breathable air. Failure to ensure breathable air source could result in
death or serious injury.
California Proposition 65
�
WARNING
Cancer and Reproductive Harm - www.P65Warnings.ca.gov.
AGLDTR6
Completed Filter
Assembly
Additional Quick Disconnect
Couplings
Pressure Gauge
Inlet Air - Pressure Regulator
Three (3) Sub-Assembly Parts