background image

V10 (3/8") Breathing Air Supply Hose 

Installation Instructions

18

V10 Br

eathing Air Supply Hose

V10 Breathing Air Supply Hose and V10 

Extension Hose Kit Assembly

breathing tube fitting

female quick-disconnect coupler

female fitting

V10 Starter Hose

V11 hose-to-hose

adaptor

V13 hose-to-pipe

adaptor

AIR SOURCE

Extension Hose

V13 hose-to-pipe
adaptor

AIR SOURCE

male quick-dis-

connect

female quick-disconnect coupler

at air source

AIR SOURCE

V12 hose-to-pipe

adaptor

V10 Starter Hose Instructions

Starter hoses include female quick-disconnect coupler crimped on one end and V13 
hose-to-pipe (3/8” NPT) adapter.  
1.  If the air source has a threaded attachment, use the supplied V13 hose-to-pipe 

(3/8” NPT) adapter to connect the threaded female fitting on the hose to the air 
source.  

2.  If the air source has a coupling attachment, refer to matching QD nipple specifica-

tion and use either a V12 (1/4”) or V13 (3/8”) to connect the nipple to the hose 
(nipple and adapter may be included with certain part numbers).  Attach QD nipple 
to QD coupling on the air source.  

3.  Connect the respirator’s breathing tube fitting to the female quick-disconnect cou-

pler on the V10 hose.  

 

NOTE:  

 

 

 Threaded seal tape should be used on all threaded attachments. Beveled end of 
adapters are for hose side of connections. 

V10 Extension Hose Instructions

Extension hoses allow you to add Bullard breathing air supply hose to your Bullard 
respirator’s starter hose or another length of extension hose.  For more information 
on maximum permissible hose lengths, configurations and necessary air pressure 
operating ranges, please refer to the User Manual Breathing Air Pressure Table.  
Extension hoses include V11 hose-to-hose adapter and V13 hose-to-pipe (3/8” NPT) 
adapter.  
1.  Remove any quick-disconnect nipple or adapter from the air source end of the 

starter hose and replace it with the V11 hose-to-hose adapter.  

2.  Connect one end of extension hose to the open end of the V11 adapter just inserted 

in the starter hose.  

3.  If the air source has a threaded attachment, use the supplied V13 hose-to-pipe 

(3/8” NPT) adapter to connect the threaded female fitting on the hose to the air 
source.  

4.  If the air source has a coupling attachment, refer to matching QD nipple specifica-

tion and use either a V12 (1/4”) or V13 (3/8”) to connect the nipple to the hose.  
Attach QD nipple to QD coupling on the air source.

 

NOTE: 

  

Threaded seal tape should be used on all threaded attachments. Beveled end of 
adapters are for hose side of connections.  

Respirable Breathing Air

Respirable breathing air must be supplied to the point-of-attachment of the approved 
breathing air supply hose. Government regulations require that all breathing air 
meet the specifications for Grade D breathing air as described in Compressed Gas 
Association Commodity Specification G-7.1-1989 and specified by federal Law 30 CFR, 
Part II, Subpart J, 11.121(b).

Point-of-attachment

Air pressure at the point-of-attachment must be regulated with the ranges specified 
on your respirator’s MSHA/NIOSH approval label.

 

NOTE

:  

 

 You can repeat the extension hose connection steps using Bullard V10 hoses. 
However, do not exceed the lengths specified on the approval label or in the 
instruction manual for your specific respirator.

DO NOT connect your Bullard breathing air supply hose to nitrogen, toxic gases, 
inert gases, or other non-breathable, non-grade D air sources. Breathing air hose 
connection fittings must be incompatible with fittings for other industrial gases as 
described by the Compressed Gas Association.

WARNING

www.bullard.com

Starter Hose

Summary of Contents for 20LF Series

Page 1: ...or stops o Air pressure gauge drops below the minimum specified in the Breathing Air PressureTable WARNING Respirator System Components 2 Respirator Operation 2 Special or Critical User s Instructions 3 Breathing Air Pressure Table 3 Respirator Assembly Component Assembly 4 Donning Doffing 4 Inspection Cleaning and Storage 5 Approval Label 6 7 Parts and Accessories 8 10 Return Authorizations 10 AC...

Page 2: ...or or pumps manufacturer s instructions for supplying Grade D air including the use of inlet inline filters air dryers carbon monoxide monitors and alarms and periodic testing and maintenance Breathing Air Supply Hoses and Hose Fittings For OSHA compliance only Bullard air supply hoses and fittings approved for use by NIOSH can be used between the breathing tube connection fitting on the wearer s ...

Page 3: ...Bayonet 27 38 29 40 30 42 31 43 34 49 37 53 40 56 42 60 Cooling Mode AC100030 AC100030B AC100030S Ind Interchange 55 72 57 74 58 75 60 76 62 80 65 83 68 86 70 88 AC100031 Schrader 56 73 58 76 59 77 61 78 63 81 66 84 70 88 72 90 AC100032 AC100033 AC100034 Snap Tite 57 75 59 77 60 78 62 79 64 82 68 86 71 88 72 91 AC100037 CEJN 58 76 60 79 62 80 63 81 65 84 68 87 71 90 73 92 AC100038 Bayonet 60 77 61...

Page 4: ...reathing tube and flow control using the instructions given on page 4 1 Connect Bullard air supply hose to an air source supplying Grade D breathable air Turn on breathing air source 2 With air flowing connect the facepiece assembly to the air supply hose see Figure 4 Pull back the sleeve on the hose coupler and insert the quick disconnect nipple on the flow control Once the fitting is secured rel...

Page 5: ...rasive cleaning or solvents may damage the lens or leave harmful residue in the facepiece if improperly rinsed or aired out Breathing Tube Inspection Inspect the breathing tube for tears cracks holes or excessive wear that might reduce the degree of protection originally provided If any signs of excessive wear are present remove the breathing tube from service and discard immediately Inspect the g...

Page 6: ...d or omit parts Use only exact replacement parts in the configuration specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for information on use and maintenance of these respirators S Special or critical User s Information and or specific use limitations apply Refer to User s Instructions before donning 2 CAUTIONS AND LIMITATIONS CF CONTINUOUS FLOW SA SUPPLIED A...

Page 7: ...46917 46915 46913 4696 469650 4696100 46916 V2050ST V20100ST V52533XXX V55031XXX V55030XXX V55033XXX V55032XXX V52531XXX V52530XXX V52532XXX V5KF5033XXX V5KF5032XXX V5KF5031XXX V5KF5030XXX V5KF2533XXX V5KF2532XXX V5KF2531XXX V5KF2530XXX V11 V12 V13 V14 V18 V19 V19B V37 V38 V17 S19432 S19442 S19443 3902 S19448 HS HSDC 36501 4612 DC70ML DC70XLXXL DC705X X X X X X X X X X X X X X X X X X X X X X X X ...

Page 8: ...35B 1 2 Industrial Interchange Brass Continuous Flow Control Fitting Free Air Pumps F35S 1 2 Industrial Interchange Stainless Steel Continuous Flow Control Fitting Free Air Pumps F37 1 4 CEJN Continuous Flow Control Fitting Compressed Air F38 1 4 Bayonet Continuous Flow Control Fitting Compressed Air F40 1 4 Industrial Interchange Adjustable Flow Control Fitting Compressed Air F40B 1 4 Industrial ...

Page 9: ...ling 50 V10 Series 3 8 ID for Compressed Air Starter Kit Includes QD Coupler 4696 V10 3 8 ID Starter Industrial Interchange 25 Black with V13 hose to pipe adapter and V17 nipple 469650 V10 3 8 ID Starter Industrial Interchange 50 Black with V13 hose to pipe adapter and V17 nipple 4696100 V10 3 8 ID Starter Industrial Interchange 100 Black with V13 hose to pipe adapter and V17 nipple 46913 V10 3 8 ...

Page 10: ... to Bullard Customer Service will provide you with written permission and a return authorization number as well as the labels you will need to return the product 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or regulations prohibit the shipment of hazardous or contaminated materials Products sus...

Page 11: ...o the hose connect the quick disconnect coupler on the air supply hose to the quick disconnectnippleontheAC1000CoolTube 4 Adjust the air pressure at the point of attachment to within the approved pressure range Figure 2 SeetheAirPressureTableonpage3 5 Dontherespiratorbyfollowingthedirectionsinyourrespiratorinstructionmanual 6 Toobtaincoolerair turntheairtemperaturecontrolknobcounterclockwise Figur...

Page 12: ... while operating the respirator A reliable air pressure gauge must be present to monitor the pressure WARNING Failure to supply the minimum required pressure at the point of attachment for your hose length will reduce airflow and could result in death or serious injury It is important to operate the Bullard climate control device in the prescribed pressure range for the particular Bullard respirat...

Page 13: ...djust the air pressure at the point of attachment Figure 2 to within the approved pressure range See the Respirator Breathing Air Pressure table in the respirator user manual 5 Putthehoodonbyfollowingthedirec tions in your respirator instruction manual If you do not have instruc tions contact Bullard Customer Service at the address or phone num bers below 6 Turn flow control valve to adjust the fl...

Page 14: ...st be conducted in an uncontaminated atmosphere Assembling the Cooling Vest 1 Insert the muffler end of the cooling vest connector hose well into the air entry sleeve of the vest Figure 1 For optional use with Bullard Airline Respirators DC50 Series Dual Cool Climate Control Tube and DC70 Vest Instruction Sheet WARNING Failure to supply the minimum required pressure at the point of attachment for ...

Page 15: ... approved pressure range found in the respirator user manual Figure 4 Operating the Dual Cool Tube 1 To obtain cooler air turn the air temperature control knobs counterclockwise Figure 3 Maximum cooling is obtained when knobs are open completely and when there is maximum airflow out of the Dual Cool tube s exhaust ports To obtain air that is closer to ambient temperature turn air temperature contr...

Page 16: ...be through the belt bracket 3 With the approved Bullard V20 air supply hose connected to the air source and with air flowing into the hose connect the quick disconnect coupler on the air supply hose to the quick disconnect nipple on the Frigitron 2000 4 Adjust the air pressure at the point of attachment to within the approved pressure range Figure 2 5 Put the hood on by following the directions in...

Page 17: ...ons 1 Connect the respirator s breathing tube fitting to the female quick disconnect cou pler on the V5 hose 2 Connect the quick disconnect nipple on the hose to the point of attachment on your breathing air source Respirable Breathing Air Respirable breathing air must be supplied to the point of attachment of the approved breathing air supply hose Government regulations require that all breathing...

Page 18: ...o hose adapter and V13 hose to pipe 3 8 NPT adapter 1 Remove any quick disconnect nipple or adapter from the air source end of the starter hose and replace it with the V11 hose to hose adapter 2 Connect one end of extension hose to the open end of the V11 adapter just inserted in the starter hose 3 If the air source has a threaded attachment use the supplied V13 hose to pipe 3 8 NPT adapter to con...

Page 19: ...emale quick disconnect cou pler on the V20 hose 2 Connect the quick disconnect nipple on the hose to the point of attachment on your breathing air source Respirable Breathing Air Respirable breathing air must be supplied to the point of attachment of the approved breathing air supply hose Government regulations require that all breathing air meet the specifications for Grade D breathing air as des...

Page 20: ...nthiana KY 41031 9303 USA Toll free within USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 ...