Fibre Channel Adapters Installation & Configuration Guide
User Diagnostics
The user diagnostic program, provided by the
smit diag
command, must be used to check
or identify a failure of the board. It allows the user to run internal loopback tests at DEC chip
level.
Internal loopback test is used to verify that the internal logic operations function correctly.
In loopback mode, the chip takes frames from the transmit list and loops them to the receive
list.
Wrap Plugs
Male D–Sub connector
plugged in the adapter
Female D–Sub connec-
tor plugged in the DB9
copper cable
connector plugged
in the (B4–B) optical
adapter
connector plugged
in the (B4–E) optical
adapter
Traces
The trace hook identifiers for the Fibre Channel Adapter (PCI) are:
•
0x047 for transmit/receive events
•
0x048 for error events
Starting the traces
•
the
trace
command:
#trace –a –j ”047 048”
•
the smit interface:
#
smit trace
and choose the sub–menu ”Start Trace”
select the ADDITIONAL event IDs to trace
give the hook ID.
Stopping the traces
•
the
trcstop
command:
#trcstop
•
the smit interface:
#smit trace
and choose the sub–menu ”Stop Trace”