Page | 9
Pool/Spa Modes
The control is equipped with two independent thermostats, one for pool temperature and one for spa temperature.
This is to allow the user to preset a temperature of their choice and switch between the two settings.
To change between pool and spa modes,
•
Press the SET button until the control reads P_S
•
Press either arrow key to switch from POL to SPA
•
Once the heating mode has been selected, it will be displayed for five seconds and then return to the actual
pool water temperature. The lights on the right side of the display indicate the selected mode.
ATTENTION!
There is a 3-minute time delay upon initiation of a heating cycle. This is to ensure that the critical
components do not fail due to short cycling of the heater.
Displaying the Temperature in °F or °C
•
Heater comes pre-set in
°F
mode. If desired in
°C
mode, please call factory for instructions
Keypad Lockout Feature
•
Locking
To lock the keypad, press the SET button for 5 seconds and the display will show spacing for a two-digit
code “_ _” at the right-hand side. Press Up and Down buttons to enter the code starting from 00 to 99. Enter
the code according to the pre-set. The control is shipped with pre-set code of 20, and then press SET button.
Each time a button is pressed the control will show “LOC” for 3 seconds and then show water temperature
•
Unlocking
To unlock the keypad, press the SET button for 5 seconds and the display will show spacing for a two-digit
code “_ _” at the right hand side. Enter the code and press the SET button. If the correct code is entered then
the control switches to show the water temperature. If the incorrect code is entered then the control will flash
“LOC” for 3 seconds and switch back to “_ _”. If nothing is entered for the next 5 seconds then the control
will switch to show water temperature and remain locked.
•
Setting the Code
With the power to the heater is off, press and hold the SET button while applying power. The control will
then show the spacing for two digits “_ _”. Enter the desired code and press SET to save it.
Changing the Set Point Temperature
To change the set point temperature, press the SET button until either POL or SPA is displayed. The programmed
temperature will be displayed. Press either the UP or DOWN arrows to change the set point temperature. After