TF with IO-Link
9 Appendix
9.1 Technical Data
TF-M-G1/2-xx-M12-TD-1D1S
Dimensions
TF-M-G1/2
TF-E-G1/2
M12x1
G1/2
EOlastic
seal
NBR
69
L = max. 1000
14
Installation depth
min. 50
Ø11
SW 36
3
32.3
12
Version:
MS
VA
Probe material:
Brass
1.4571
Max. operating pressure:
5 bar
10 bar
Connection:
G1/2
G1/2
Medium temperature:
-20 °C to +80 °C
Ambient temperature:
-20 °C to +70 °C
Lengths:
280, 370, 500 (standard)
variable to max. 1000 mm
Input value
Sensor element:
Pt100 Class B DIN EN 60751
Tolerance Pt100:
±0.8 °C
Operating voltage (U
B
):
18 - 30 VDC
Measuring range:
-20 °C to +120 °C
Output:
IO-Link
IO-Link
Revision 1.1
Baudrate:
COM3 (230.4 k)
SIO Mode:
Yes
Min. Time Period
10 ms
9.2 Standard pin assignment
Connector
M12
Dimensions
Number of pins
4-pin
DIN EN
61076-2-101
IP rating
IP67*
*with IP67 cable box attached
Version
1D1S
Plug
M12 4-pin
Connection schematic
Pin
1
+24 V DC
2
S2 (PNP max. 200 mA)
3
GND
4
C/Q (IO-Link)
11
Bühler Technologies GmbH
BE140016 ◦ 09/2020
Summary of Contents for TF with IO-Link