background image

GEN7500TRI 7500 Surge Watt / 6000 Running Watt Portable Tri Fuel  LPG, Gasoline or Natural Gas Generator with Electric Start Manual 

 

 

16 

USING THE GENERATOR 

After the engine has been running for several minutes, electrical devices may be connected to this generator. 
 

AC Usage 

Electrical devices running on AC current may be connected according to their wattage requirements. The rated (running) and surge wattage: 
 

ITEM # GEN7500TRI Rated (Running) Wattage 

6000 

ITEM # GEN7500TRI Surge Wattage 

7500

 

 
The 

rated (running) wattage 

corresponds to the maximum wattage a generator can output on a continuous basis. 

 
The 

surge wattage 

corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a 

refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices 

typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement. 
 
The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself. 
To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add 
these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected 
devices exceeds the rated wattage of the generator, DO NOT connect all of the devices. Select a combination of the electrical devices that will have 

a total wattage less than or equal to the rated wattage for the generator, i.e., no more than 6000 for this generator. 
 

                                                                                        

   

This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage equal to or 
less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a generator. 
 
A device's rated (running) wattage should be listed somewhere on the device itself and/or in its manual. If the wattage specification for a device is not 

available, the wattage can be calculated by multiplying the Voltage requirement (120 or 240) by the Amperage drawn. 
Watts = Volts x Amperes 
Or, the wattage required by a device can be estimated by using the following chart (see Figure 7). The chart provides only estimates and it is better 
to know the exact wattage of each electrical device to be powered by this generator. 

 

Electrical Device 

Rated (Running) Watts 

Additional Surge Watts 

air compressor (1 HP) 

1500 

3000 

air compressor (1 - 1/2 HP) 

2500 

2500 

airless sprayer (1/3 HP) 

600 

1200 

box fan 

300 

600 

clock radio AM/FM 

300 

coffee maker 

1500 

computer w/17 inch monitor 

800 

deep freezer 

500 

500 

electric drill (1/2 HP) 

1000 

1000 

DVD/CD player or VCR 

100 

furnace fan blower (1/2 HP) 

800 

1300 

garage door opener (1/2 HP) 

480 

520 

hot plate 

2500 

light bulb (75 watt) 

75 

microwave oven (1000 watt) 

1000 

quartz halogen work light 

1000 

refrigerator/freezer (18 Cu. Ft.) 

800 

1600 

saw - circular (7 1/4 inch) 

1500 

1500 

saw - miter (10 inch) 

1800 

1800 

saw - reciprocating 

960 

1040 

security system 

180 

electric stove - single element 

1500 

sump pump 

800 

1200 

television (27 inch color) 

500 

electric water heater (40 gallon) 

4000 

window air conditioner (10000 BTU) 

1200 

1800 

window fan 

300 

600 

Figure 7 - Estimated wattage requirements for common electrical devices.  

 

Summary of Contents for GEN7500TRI

Page 1: ...ou experience a problem or need parts call customer service at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required IF THERE IS ANY QUESTION ABOUT A CONDITION BE...

Page 2: ...e center For owners located more than 100 miles from an authorized service center Buffalo Corp will in its sole discretion either pay for shipping costs to and from an authorized service center provid...

Page 3: ...2 Connect Fuel 12 Step 3 Ground The Generator 13 Subsequent Use Of This Generator 13 Step 1 Verify Oil Level 13 Step 3 Ground The Generator 14 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage...

Page 4: ...oderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage Legal Requirements Federal and or State Occup...

Page 5: ...This generator produces powerful voltage which can result in electrocution ALWAYS ground this generator before using it See Ground the Generator section in this manual Only electrical devices should b...

Page 6: ...in the storage and use areas Storage areas must meet national electric codes for class 1 hazardous areas Propane and Natural Gas smells like rotten eggs a skunk s spray or a dead animal IF YOU SMELL...

Page 7: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 7...

Page 8: ...Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 8 In addition to the previously described safety information familiarize yourself with all safety and h...

Page 9: ...omer service DO NOT RETURN THIS GENERATOR TO THE RETAILER Item List Set of 2 DC connector wires for charging 12 Volt automotive type batteries Spark plug wrench 5 Ft Regulator Hose Kit YOU MUST USE TH...

Page 10: ...SUPPLIED REGULATOR FOR SAFE OPERATION THIS IS NOT USED FOR NATURAL GAS ATTENTION The Air fuel Mixer is not adjustable Tampering with the governor can damage your generator and electrical devices and w...

Page 11: ...local natural gas professional advise this information Fuel Consumptions Fuel Load Natural Gas 160 cu ft hr 160 000 BTU HR Have your local fuel supplier install a protected fuel connection at the outs...

Page 12: ...from the package this generator contains no oil in the engine crankcase The correct quantity of oil is equal to the oil capacity of the engine crankcase and is 38 fluid oz Add the correct quantity of...

Page 13: ...with a gas hose no less than 3 8 inside diameter no longer than 10 ft 3m and to the gas inlet fig 3 Do not use the LP regulator hose for NG If using LPG or NG be sure that the carburetor is free of ga...

Page 14: ...tion titled Using the Generator for the First Time of this manual If not review this section now Step 1 Verify Oil Level Even though this generator is equipped with an automatic shutoff to protect it...

Page 15: ...used first install the battery using the two included cables one red and the other black according to the following procedure 1 Attach one end of the red cable to the positive terminal on the battery...

Page 16: ...e less than or equal to the rated wattage for the generator i e no more than 6000 for this generator This generator can run at its surge wattage capacity for only a short time Connect electrical devic...

Page 17: ...though this Generator has an overall rated wattage of 6000 do not attempt to draw more than 20 AMPS from any set of Two receptacles of the 120 Volt outlets Draws higher than 20 Amps will damage this...

Page 18: ...charging wire to the positive terminal of the battery and the black charging wire to the negative terminal of the battery 2 Connect the plug end of the wire to the 12V DC outlet on this generator 3 St...

Page 19: ...ck X Clean X Fuel Filler Cap Clean X Spark Plug Check Clean X Clean X Figure 10 Recommended maintenance schedule Cleaning the Generator Always try to use this generator in a cool dry place If this gen...

Page 20: ...the crankcase underneath the oil filler dipstick cap as illustrated in Figure 12 3 Allow all the oil to drain from this generator 4 Replace the oil drain plug and tighten with a 12 mm wrench NOTE Neve...

Page 21: ...is Champion RN9YC STORAGE TRANSPORT PROCEDURES Never place any type of storage cover on this generator while it is still hot When transporting or storing this generator for extended time Allow generat...

Page 22: ...is dirty Clean or replace air filter Loose wiring harness connection Turn off generator then check wiring behind control panel and at the end of generator for loose connection If wires are loose tight...

Page 23: ...attage W 6000 Surge Wattage W 7500 Rated Voltage V 120 240 Rated Amperage 25A 25A 25A 25A at 120 V 30 A at 240 V 30 A at 120 RV Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breake...

Page 24: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 24 PARTS DIAGRAM...

Page 25: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 25...

Page 26: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 26...

Page 27: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 27...

Page 28: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 28...

Page 29: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 29...

Page 30: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 30...

Page 31: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 31...

Page 32: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 32...

Page 33: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 33...

Page 34: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 34...

Page 35: ...GEN7500TRI 7500 Surge Watt 6000 Running Watt Portable Tri Fuel LPG Gasoline or Natural Gas Generator with Electric Start Manual 35 WIRING DIAGRAM...

Page 36: ...owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power equipment engine or a part has failed due to abuse neglect improper maintenance or unapproved modific...

Page 37: ...l not reduce the warranty obligations of Buffalo Corp 10 Add on or modified parts that are not exempted by the Air Resources Board may not be used The use of any non exempted add on or modified parts...

Reviews: