background image

5

UK

Telephone Helpline: 0845 146 2887

Troubleshooting

Fault

Probable Cause

Solution

Indicator Light does 

not come on & unit 

does not heat up

The unit is not switched on

Check the unit is plugged in correctly and 

switched on

Plug and lead are damaged

Call BUFFALO agent or qualified Technician

Fuse in the plug has blown

Replace the plug fuse

Power supply

Check power supply

Internal wiring fault

Call BUFFALO agent or qualified technician

Thermostat has failed

Call BUFFALO agent or qualified technician

Indicator Light 

comes on but unit 

does not heat up

Heating element has failed

Call BUFFALO agent or qualified technician

Thermostat has failed

Call BUFFALO agent or qualified technician

Loud noises

The appliance has not been installed 

in a level or stable position

Check installation position and change if 

necessary

The appliance is too close to a wall 

or other object

Move to a well-ventilated position.

Odour from the unit Unit is not cleaned for long time

Clean the unit thoroughly

Technical Specifications

Model

Voltage

Power Current Temperature 

range

Capacity

Dimensions

h x w x d mm

Weight

CW147

220-240V 

50Hz

500W

2.2A

30°C ~ 90°C

46L

420 x 773 x 336

15kg

CW148

220-240V 

50Hz

800W

3.5A

30°C ~ 90°C

68L

420 x 1127 x 336

22kg

CW147-CW148_UK_A5_v1_171206.indb   5