Buffalo APB CC190-A Instruction Manual Download Page 4

3

Cleaning, Care & Maintenance

Always turn off and disconnect the appliance from the power supply before cleaning.

Use soapy water and a damp cloth to clean the exterior of the appliance. 

Dry  thoroughly  after cleaning.

Descaling

In hard water areas lime scale can build up within the appliance after prolonged use. To descale the
appliance:

1.

Pour a solution of descaler and water into the appliance.

2.

Brush the interior gently with a soft bristled brush.

3.

Discard the solution collected in the jug.

4.

Fill the appliance with clean water and turn back On to flush out the system. 

Flush out the system thoroughly to remove any descaler residue. 

5.

The appliance is now ready for use.

Troubleshooting

Note: Use a suitable descaler and always follow the instructions on the container.
BUFFALO recommend that this appliance is descaled every 3 months or more frequently 
in hard water areas.

Fault

Probable Cause

Action

The unit is not 

working 

The unit is not switched on

Check the unit is plugged in correctly and 

switched on

Plug and lead are damaged

Call BUFFALO agent or qualified technician

Fuse in the plug has blown

Replace the plug fuse

Power supply

Check power supply

Internal wiring fault

Call BUFFALO agent or qualified technician

Power light 

comes on but 

water does not 

reach 

temperature

Thermostat fault

Call BUFFALO agent or qualified technician

The tap is 

leaking

The tap has become loose

Tighten the tap handle

Reviews: