ITEM # GENMAX1500   1500 Surge Watt / 900 Running Watt Portable 2-Cycle Generator Manual 

 

 

                                                                                 

 

 

Flammable liquid gas under pressure. Can form explosive mixtures with air. May cause frostbite. 

In Case Of Inhalation

: Persons suffering from 

lack of oxygen should be removed to fresh air. If victim is not breathing, administer artificial respiration. If breathing is difficult, administer 
oxygen. Obtain prompt medical attention. 

In Case Of Eye Contact

: Contact with liquid or cold vapor can cause freezing of tissue. Gently flush 

eyes with lukewarm water. Obtain medical attention immediately.

 In Case Of Skin Contac

t:  Contact with liquid or cold vapor can cause 

frostbite. Immediately warm affected area with lukewarm water not to exceed 105°F (40°C). 

Fire And Explosion Hazards: 

Propane is easily 

ignited. It is heavier than air, therefore, it may collect in low areas or travel along the ground where an ignition source may be present. Pressure 
in a container can build up due to heat, and it may rupture if pressure relief devices should fail to function. 

Storage:

 Cylinders should be stored 

upright with valve protection cap in place and firmly secured to prevent falling or being knocked over. Protect cylinders from physical damage; 
do not drag, roll, slide or drop. Use a suitable hand truck for cylinder movement. Post "No Smoking or Open Flames" signs in the storage areas. 
There should be no sources of ignition. All electrical equipment should be explosion proof in the storage and use areas. Storage areas must 
meet national electric codes for class 1 hazardous areas. 
 

                                                                                 

 

Usage:

 

Consult a physician(s) before using this generator if using a pacemaker. 

Electromagnetic fields in close proximity to a heart 

pacemaker could cause a pacemaker to malfunction or fail. Caution is necessary when near the engine’s recoil starter. 
 

                                                                                 

 

Usage:

 

Prolonged exposure to high noise levels can be hazardous to hearing. 

Always wear ANSI-approved hearing protection when 

operating or working around the generator when it is running. 
 
 

Summary of Contents for GENMAX1500

Page 1: ...ttp www buffalotools com or call customer service at 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRANTY FOR FUTURE REFERENCE ATTENTION 2 CYCLE OIL AND GASOLINE IS NOT IN...

Page 2: ...apply only for the contiguous states excluding the states with high altitude areas identified in 40 CFR part 1068 Appendix III To exercise this warranty DO NOT RETURN TO RETAILER Instead call Customer Service toll free at 1 866 460 9436 email address info buffalotools com and you will be instructed on where to take the engine for warranty service Take the generator and proof of purchase your recei...

Page 3: ... hazardous situation which if not avoided could result in death or serious injury CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage Legal Requirements Federal and or State Occupational Safety and He...

Page 4: ...n and create fires when utility power is restored Do not use this generator in wet conditions rain snow active sprinkler system wet hands etc Always keep this generator dry and operate it with dry hands Do not touch bare wires or outlets receptacles Do not allow children or non qualified persons to operate this generator High Temperatures This generator produces heat when in operation Temperatures...

Page 5: ... source may be present Pressure in a container can build up due to heat and it may rupture if pressure relief devices should fail to function Storage Cylinders should be stored upright with valve protection cap in place and firmly secured to prevent falling or being knocked over Protect cylinders from physical damage do not drag roll slide or drop Use a suitable hand truck for cylinder movement Po...

Page 6: ...ITEM GENMAX1500 1500 Surge Watt 900 Running Watt Portable 2 Cycle Generator Manual 6 ...

Page 7: ...MAX1500 1500 Surge Watt 900 Running Watt Portable 2 Cycle Generator Manual 7 In addition to the previously described safety information familiarize yourself with all safety and hazard notices on this generator ...

Page 8: ...ector wires for charging 12 Volt automotive type batteries Spark plug remover Screwdriver GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator To prevent electrical shock from faulty appliances the generator should be grounded Connect a length of heavy wire between the ground terminal and the ground source Consult with a qualified electr...

Page 9: ...el mixture of gasoline and 2 stroke oil Use only a mix of unleaded gasoline and 2 stroke oil in a ratio of 50 1 The generator is delivered without fuel mixture and must be filled prior to start up operation Attention Always add fuel mixture when the generator is switched off Please ensure that the fuel switch is in the OFF position Open the tank cover and fill it with max 1 gallon of fuel mixture ...

Page 10: ...he earth Grounding codes can vary by location Contact a local electrician for information on grounding regulations for your area STARTING THE GENERATOR STOP Before starting this generator confirm that all the steps in the section titled Preparing the Generator for Use of this manual have been correctly completed If unsure about how to perform any of these steps call 1 866 460 9436 Monday Friday 8 ...

Page 11: ...urge wattage capacity for only a short time Connect electrical devices requiring a rated running wattage equal to or less than the rated wattage of this generator Never connect devices requiring a rated wattage equal to the surge wattage of a generator A device s rated running wattage should be listed somewhere on the device itself and or in its manual If the wattage specification for a device is ...

Page 12: ...RDS Long or thin cords can require more wattage from a generator to power an electrical device Figure 9 shows the recommended cords according to the power requirement of the electrical device When using cords that exceed these specifications allow for the electrical device to have a slightly higher rated wattage requirement Device Requirements Max Cord Length ft by Wire Gauge Amps Watts 120V Watts...

Page 13: ...n disconnecting always disconnect the wires from this generator first to avoid a spark Storage batteries emit highly explosive hydrogen gas when charged Batteries also contain acid which can cause severe chemical burns Do not allow open flames or cigarettes nearby for several minutes after charging a battery Always wear protective goggles and rubber gloves when charging a battery If battery acid g...

Page 14: ...rator in a cool dry place If this generator becomes dirty the exterior can be cleaned with a damp cloth soft brush vacuum and or pressurized air Never clean this generator with a bucket of water and or a hose as water can get inside and cause a short circuit or corrosion Never use gasoline to clean parts of this generator Spark Plug Maintenance The spark plug is essential for proper engine operati...

Page 15: ...ry Pour a small amount of motor oil onto the filter ring out ALL excess oil and reinstall the foam filter element in the generator Emptying the Carburetor To store this generator for extended time the fuel needs to be drained from the carburetor To drain the gasoline from the carburetor turn the fuel valve to the off position while the engine is running The generator will shut down when all the ga...

Page 16: ...ole Single Phase AC Output Rated Wattage W 900 Surge Wattage W 1500 Rated Voltage V 120 Rated Amperage 15 Rated Frequency Hz 60 Phase Single DC Output Voltage V 12 Circuit Breaker Amperage A 8 Engine Engine Type 2 stroke single cylinder with forced air cooling system Engine Displacement 72cc Engine Model HP 2 0 Compression Ratio 8 1 Ignition System CDI Starting System Recoil Bore Stroke mm 47 x 41...

Page 17: ...ITEM GENMAX1500 1500 Surge Watt 900 Running Watt Portable 2 Cycle Generator Manual 17 PARTS DIAGRAM ...

Page 18: ...ITEM GENMAX1500 1500 Surge Watt 900 Running Watt Portable 2 Cycle Generator Manual 18 PARTS LIST ...

Page 19: ...ITEM GENMAX1500 1500 Surge Watt 900 Running Watt Portable 2 Cycle Generator Manual 19 PARTS DIAGRAM ...

Page 20: ...ITEM GENMAX1500 1500 Surge Watt 900 Running Watt Portable 2 Cycle Generator Manual 20 PARTS LIST ...

Page 21: ...rces Board Buffalo Corp warrants to the ultimate purchaser and each subsequent purchaser that the small off road engine SORE 1 has been designed built and equipped so as to conform with all applicable regulations and 2 is free from defects in materials and workmanship that cause the failure of a warranted part to conform with those regulations as may be applicable to the terms and conditions state...

Page 22: ... Board EMISSION WARRANTY PARTS LIST 1 Fuel Metering System a Gasoline carburetor assembly and its internal components b Carburetor gaskets c Fuel line d Clamps e Fuel tank f Fuel line fittings g Pressure regulator if equipped h Mixer assembly and its internal components if equipped 2 Air induction system including a Intake pipe manifold b Air cleaner 3 Ignition system including a Spark plug b Igni...