Buffalo Tools GEN2000 Instruction Manual Download Page 13

GEN2000 Portable Gasoline Generator  

 

 

13 

Subsequent Use of this Generator 

 
For subsequent uses of this generator after the first use, certain steps still must be completed to prepare it for operation. 
 

IMPORTANT: Be familiar with the procedures described in the previous section titled “Using the Generator for the First Time” of this 
manual. If not, review this section now. 
 

Step 1 - Verify Oil Level 

 
It is important to check the oil level in the engine crankcase before each use to ensure that there is sufficient quantity. 
1. Verify that this generator is on a level surface. 

2. Unscrew the oil filler/dipstick cap from the engine. 

3. With a dry cloth, wipe the oil off of the dipstick that is located on the inside of the cap. 

4. Fully insert the dipstick without screwing the filler/dipstick cap and then remove again. There should be oil on the dipstick. If there is no oil on the 

dipstick, or oil is visible only at the very end of the dipstick, add oil until the engine crankcase is filled. (See “Changing/Adding Oil” in the 

“Maintenance/Care” section of this manual). 

5. Confirm that the oil filler/dipstick cap is properly screwed in place when finished verifying the oil level. 
 

Step 2 - Verify Gas Level 

 

Before starting this generator, verify that there is sufficient gasoline in the fuel tank. If necessary, add fresh unleaded gasoline with an octane rating 
of 87 or higher according to “Step 2 - Add Gasoline” of the “Using this Generator for the First Time” section of this manual. 
 

Fuel Tank Capacity (gallons) 

1.2 

Fuel Type 

Fresh, Unleaded Gasoline Octane Rating 87 or Higher 

 

                               

                                                             

  

Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns.

 

• Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power 
tools, etc. 
• Always allow several minutes for the engine to cool before refueling. 

• Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a fire hazard and causes environmental 
damage. 
 

IMPORTANT: 

• Use only fresh UNLEADED gasoline with an octane rating of 87 or higher. 
• Never use old and/or contaminated gasoline. 

• Never use a mixture of oil and gasoline. 
• Avoid getting dirt and/or water in the fuel tank. 
• Never store generator for extended time with gasoline in the fuel tank. 
 

Step 3 - Ground the Generator 

 

                               

                                                            

   

Failure to properly ground this generator can result in electrocution.

 

 
Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable 
grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a 
copper or brass grounding rod that is driven into the earth. 
 

Grounding codes can vary by location. Contact a local electrician for information on grounding regulations for your area. 
 

Summary of Contents for GEN2000

Page 1: ...to change this product at any time without prior notice IF THERE IS ANY QUESTION ABOUT A CONDITION BEING SAFE OR UNSAFE DO NOT OPERATE THIS PRODUCT DO NOT RETURN THIS GENERATOR TO THE RETAILER If you...

Page 2: ...t A C Outlet 1 12 Volt D C Outlet Engine Run Time 9 Hours 50 Load Low Oil Shutdown EPA Approved Noise Level 68dB 0 Load Oil Capacity 12 ounces Fuel Capacity 1 2 gallon Fuel Type Unleaded Gasoline Only...

Page 3: ...f This Generator 13 Step 1 Verify Oil Level 13 Step 2 Verify Gas Level 13 Step 3 Ground The Generator 13 STARTING THE GENERATOR 14 USING THE GENERATOR 15 AC Usage 15 DC Usage 16 STOPPING THE GENERATOR...

Page 4: ...me to the owner to make the warranty repair or pay for the repair to be made at a local non authorized service center The provisions of this paragraph apply only for the contiguous states excluding th...

Page 5: ...r s electricity does not feed back into the electric utility power lines WARNING Do not use this generator to provide power for emergency medical equipment or life support devices Carbon Monoxide Gas...

Page 6: ...p Loosen the cap slowly to relieve pressure in the fuel tank Avoid spilling fuel Do not fill the fuel tank above the upper limit line Gasoline may expand during operation Do not fill to the top of the...

Page 7: ...GEN2000 Portable Gasoline Generator 7...

Page 8: ...GEN2000 Portable Gasoline Generator 8 In addition to the previously described safety information familiarize yourself with all safety and hazard placards on this generator...

Page 9: ...s Generator Verify that all items are included STOP If there are missing items call 1 866 460 9436 Monday Friday 8 AM 4 PM Central Time for customer service DO NOT RETURN THIS GENERATOR TO THE RETAILE...

Page 10: ...Protector 12 12 Volt DC Outlet 13 Grounding Terminal 1 Fuel Tank Cap 2 Control Panel 3 Oil Access 4 Fuel Cock 5 Carburetor Choke Lever 6 Air Filter Cover 7 Recoil Starter GENERATOR COMPONENTS Observe...

Page 11: ...GENERATOR WILL NOT START DOUBLE CHECK THAT THE OIL LEVEL IS COMPLETELY FULL AND ALMOST OVERFLOWING This generator requires engine oil to function Engine oil is a major factor affecting engine performa...

Page 12: ...and do not fill the fuel tank to the very top 4 Securely tighten the fuel tank cap and immediately wipe up any spilled gasoline with a dry cloth Fuel Tank Capacity gallons 1 2 Fuel Type Fresh Unleaded...

Page 13: ...87 or higher according to Step 2 Add Gasoline of the Using this Generator for the First Time section of this manual Fuel Tank Capacity gallons 1 2 Fuel Type Fresh Unleaded Gasoline Octane Rating 87 or...

Page 14: ...hen pull briskly to start the engine Gently return the cord into the generator to avoid damage to the starter or housing Never allow the cord to snap back 7 If the engine fails to start repeat step 6...

Page 15: ...d wattage for the generator This generator can run at its surge wattage capacity for only a short time Connect electrical devices requiring a rated running wattage equal to or less than the rated watt...

Page 16: ...low the engine to run for several minutes after it has been started 2 Confirm that the electrical device is switched off prior to plugging it into this generator 4 Turn on the connected electrical dev...

Page 17: ...generator is running Allow this generator to cool before commencing any maintenance procedures Keep heat sparks and flame away Improper maintenance and or failure to correct any problems prior to oper...

Page 18: ...should be changed every 6 months or for every 100 hours of use or when the oil has become contaminated with water and or dirt To drain the oil from this generator 1 Place a bucket underneath this gen...

Page 19: ...k plug from this generator by using the included spark plug wrench 3 Visually inspect the spark plug If it is cracked and or chipped discard and install a new spark plug A E7RTC spark plug such as NGK...

Page 20: ...line and add gasoline conditioner 2 months to 1 year Empty the fuel tank See Emptying the Fuel Tank in the Maintenance Care section 1 year or more Empty the fuel tank See Emptying the Fuel Tank in the...

Page 21: ...Bad connecting wires cables Try a different extension cord Bad electrical device connected to generator Disconnect device try connecting another device Generator is overloaded Reduce draw on generato...

Page 22: ...1 Oil Seal 17 30 6 1 3 JF152FFH 01 03 Dipstick 1 4 JF152FFH 01 12 O Ring 1 5 ZJ151FEH 01 03 Cover Crankcase 2 6 GB T276 Bearing 1 7 JF152FFH 01 02 Gasket Crankcase 2 NO PART NO DESCRIPTION QTY 1 JF152...

Page 23: ...assy 1 4 JF152FFH 01 08 Guide dowel 4 5 GB T276 1994 Bearing 1 6 QJ168QDJ 05 04 Pin 1 7 JF152FFH 01 09 Clipboard 1 8 GB T16674 1 2004 Bolt M6 12 4 9 ZJ151FEH 01 01 Plate 1 1 10 JF152FFH 01 01 Washer s...

Page 24: ...GEN2000 Portable Gasoline Generator 24 CYLINDER HEAD ASSEMBLY...

Page 25: ...rod bolt 2 NO PARTS NO DESCRIPTION QTY 1 JF152FFH 06 01 01 Adjustment Centrifugal 1 2 JF152FFH 06 01 03 Pin 2 3 JF152FFH 06 01 02 Block Centrifugal 2 4 QJ182QDP 06 06 Cover Push rod 1 5 QJ168QDJ 05 0...

Page 26: ...1 2 1 JF152FFH 08 01 01 Starter cover 1 1 2 2 JF152FFH 08 01 07 Pull rope 1 1 2 3 ZJ151FEH 04 01 02B Clockwork spring 1 1 2 4 JF152FFH 08 01 01 Rotary table 1 1 2 5 JF152FFH 08 01 08 Spring return 2...

Page 27: ...ter Assy 1 3 JF152FFH 10 01 Air Cleaner Gasket 1 4 JF156FFH 12 03 02 Oil Hose 1 5 JF168FJH 10 03 03 Clip 8 5 2 NO PARTS NO DESCRIPTION QTY 1 JF156FFH 2 09 01 Carburetor Assembly 1 2 JF156FFH 09 02 01...

Page 28: ...3 13 QJ3200 01 04 Standard Outlet 1 14 QJ6500 02 05 DC Protector 8A 8 15 10412350001 Capacitance 12Uf 350V 1 16 QJ6000 02 02 Jacket 1 17 QJ1200 02 02A Sheath 1 18 KE2000 02 02D Cable 1 19 KE2000 02 0...

Page 29: ...ler 1 NO PART NU DESCRIPTION QTY 1 KE2000 06 01A Frame Welding Components 1 2 GB T5789 1986 Bolt M6x10 8 3 KE2000 06 01 Fuel Tank Protecting Plate 2 4 QJ1200 06 03 Right Shockproof Mounting Feet 1 5 G...

Page 30: ...for your failure to ensure the performance of all scheduled maintenance As the power equipment engine owner you should however be aware that Buffalo Corp may deny your warranty coverage if your power...

Page 31: ...ed in the performance of any warranty maintenance or repairs and must be provided without charge to the owner Such use will not reduce the warranty obligations of Buffalo Corp 10 Add on or modified pa...

Page 32: ...GEN2000 Portable Gasoline Generator 32 2015 11...

Reviews: