DHS660 Digital Scale 660 Lb, Max Capacity Instruction Manual 

 

 

DIGITAL CONTROL PANEL INSTRUCTIONS 
 

 

    A         

B        C

                    A1             A2               A3            A4   

 

A

TO TURN POWER ON

, press Power Button (A) when unit is OFF. (Batteries must be installed) 

     

TO TURN POWER OFF

, press Power Button (A) when unit is ON (A4). 

(A1: Press Power Button (A) for 1 second.) 

(A2: After 1 second, the display shows power has been initialized.)  

(A3: Scale detects load and auto-zeros itself.) 

(A4: If the power is ON, press Power Button (A) for 1 second and the scale will turn off.) 

 

       

    

A

         B        

C

                      B1               B2  

B

: Press HOLD Button

 (B) to Lock the display 

(B1: Display is not locked). 

(B2: HOLD appears on the display and indicates the display is locked.)  

 

 

     

A         B  

      C                      C1               C2            C3      

C

Press TARE Button

 (C) to store weight as Tare (C1). (C2: The TARE display is locked.)  

(C1: Gross weight is displayed). 

(C2: After pressing Tare (C), TARE is displayed and weight turns to zero. (If weight is not stable, or  

under/over a certain weight, Tare will not work.) 

(C3:  Press Tare (C) , and scale resumes in Gross weight.) 

 

 

B  

          B         C                      D1           D2             D3             D4             D5

 

D

Adjust Scale Settings

 

(D1: Press HOLD (B) and TARE (C) at same time to enter Setting Mode). 

(D2: Press TARE (C) to enter Auto-Off option

. Press HOLD (B) to change Auto-Off option.) 

(D3: Auto-Off can be set to 0 (Disabled), 5 (5 min), 15 (15 min), 30 (30 min) and 60 (60 min). 

(Press TARE (C) to enter Auto-Zero option. Press HOLD (B) to change Auto-Zero option.) 

(Auto-Zero can be set to 0 (disabled), 2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20 (20%F.S.), 50 (50%F.S.) 

(D4: Press TARE (C) to enter Manual-Zero option. Press HOLD (B) to change Manual-Zero option. 

(Manual-Zero can be 0 (disabled), 2 (2%F.S.), 4 (4%F.S.), 10 (10%F.S.), 20 (20%F.S.), 50 (50%F.S.) 

(D5: Press TARE (C) to enter Back Light option. Press HOLD (B) to change Back Light option.)  

(Back Light can be set to Off (disabled), 5 (5 sec), 15 (15 sec), 30 (30 sec), 60 (60 sec), YYY (never). 

Summary of Contents for DHS660

Page 1: ...ONS PROBLEMS CALL CUSTOMER SERVICE If you experience a problem have questions or need parts for this product call Customer Service at 1 636 532 9888 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRANTY FOR FUTURE REFERENCE FEATURES Requires 3 AA Batteries Batteries Included Min...

Page 2: ...yed C2 After pressing Tare C TARE is displayed and weight turns to zero If weight is not stable or under over a certain weight Tare will not work C3 Press Tare C and scale resumes in Gross weight B B C D1 D2 D3 D4 D5 D Adjust Scale Settings D1 Press HOLD B and TARE C at same time to enter Setting Mode D2 Press TARE C to enter Auto Off option Press HOLD B to change Auto Off option D3 Auto Off can b...

Page 3: ...ight is set to 5 15 30 or 60 the scale turns off back light in corresponding seconds after it becomes stable When Back light is set to Off Back Light is disabled and never turns on When Back Light is set to on scale never turns off Back light no matter it is stable or not Press TARE C to exit the Settings Mode E1 ...

Page 4: ...w and may cause personal injury and or property damage if contacted The scale is not insulated and contact with electric source will cause electrical shock Do not overload the scale Do not exceed the Max Weight Capacity 660 lbs Do not expose the scale to extreme heat or cold The scale is designed to work best at normal room temperature Do not leave a load hanging on the scale for an extended perio...

Reviews: