8
Installing the collectors
SKR6.1R, SKR12.1R - Subject to technical modifications.
25
8.4
Fitting the bridging set (accessory)
To improve the appearance of the space between two
collectors, the bridging set can be fitted as an accessory.
Standard delivery
• 1 x thermal insulation (45 mm wide) with self-adhesive
closure
• 1 x cover panel
• 2 x connection plugs with metal pin
Installation
The installation requires the collectors to be aligned
precisely.
1. Place the thermal insulation over both fittings from
below and seal using the self-adhesive tab.
2. Push on the cover panel from above and lock in place
at the back of the header boxes.
Fig. 35 Top of collector at header box: installing thermal
insulation and cover panel
The plug that is part of the bridging set holds both
collector frames together with the correct clearance.
1. Remove the original plugs from the collector frame
profiles.
2. Insert the new connection plugs into the profiles.
3. Drive the metal pin with a hammer into the side of the
plug.
Fig. 36 Collector bottom: replacing the plugs
6 720 647 042-13.1ITL
6720646203-42.1ST
1.
2.
3.