6
Maintenance
Logalux PL750/2 S - Changes may be made following technical improvements!
24
6.4
Replacement of Magnesium Anode
Rod
V
Remove M8 nut [10] to release the ground wire eyelet
[8].
V
Remove M8 nut [7].
V
Remove the clean out cover [3] and gasket [2] from the
magnesium anode [1].
V
Replace the magnesium anode.
V
Fit the new magnesium anode together with all small
parts supplied with it, as shown in Fig. 18.
Fig. 18 Replacement of magnesium anode rod
1
Magnesium anode
2
Gasket
3
Clean out cover
4
Insulating sleeve
5
Flat washer
6
Lock washer
7
Hex head nut M8
8
Ground wire eyelet
9
Lock washer
10
M8 nut