background image

4

 

Shutting down the heating system

Logano plus – 6720865368 (2019/05)

8

4

Shutting down the heating system

4.1

Shutting down the heating system via the control unit

NOTICE: 

Frost damage!

If the heating system is not standing in a frost-proof room and is not in 
operation, it may freeze up when exposed to frost. In summer mode or if 
heating mode is blocked, only the device frost protection remains active.

▶ Leave the heating system switched on at all times whenever possible, 

and set the flow temperature to at least 30 °C,

-or-

▶ Protect the heating system against frost by having the heating and 

DHW pipes drained by a contractor from the lowest point.

▶  Shutting down the heating system via the ON/OFF switch at the 

control unit (

Chapter  2.3.1).

4.2

Shutting down the heating system in an emergency

Only use the boiler room circuit breaker or heating system emergency 
stop switch to switch off the heating system in an emergency.

▶ Never risk your own life. Your own safety is paramount.
▶ Close off the fuel supply installed on site.
▶ Isolate the heating system from the mains power supply via the 

heating system emergency stop switch or the main circuit breaker.

5

Inspection and maintenance

5.1

What makes regular service important?

Heating systems should be regularly serviced for the following reasons:

• To maintain a high level of efficiency and to operate the heating 

system economically (low fuel consumption)

• To achieve a high level of operational reliability
• To maintain the cleanest possible combustion

NOTICE: 

Material damage due to a lack of or incorrect cleaning and service.

▶ Have the heating system inspected, maintained and cleaned once a 

year by a certified heating contractor.

▶ We recommend you enter a contract covering an annual inspection 

and demand-based maintenance.

5.2

Cleaning and care

To clean the boiler:
▶ Do not use abrasive or aggressive cleaning agents.
▶ Clean the casing with a damp cloth (soapy solution).

6

Troubleshooting 

6.1

Recognising the operating condition and clearing 
faults

NOTICE: 

Frost damage!

If the heating system is not standing in a frost-proof room and is not in 
operation, it may freeze up when exposed to frost. In summer mode or if 
heating mode is blocked, only the device frost protection remains active.

▶ Leave the heating system switched on at all times whenever possible, 

and set the flow temperature to at least 30 °C,

-or-

▶ Protect the heating system against frost by having the heating and 

DHW pipes drained by a contractor from the lowest point.

If a fault has developed, the fault code flashes on the control unit display.

For more information on rectifying the problem or on possible faults, 
refer to the corresponding technical documentation of the installed 
control unit.

If the fault cannot be cleared:

▶ Note down the fault message and notify a heating contractor.

Summary of Contents for 7736603544

Page 1: ...Read carefully prior to operation 6720865368 2019 05 GB Operating instructions for users Gas fired condensing boiler Logano plus 0010018644 002 GB402 395 620 ...

Page 2: ...d safety instructions 2 1 1 Explanation of symbols 2 1 2 General safety instructions 3 2 Product Information 5 2 1 Declaration of Conformity 5 2 2 Water quality fill and top up water 5 2 3 Product overview 5 2 3 1 Product information 5 3 Commissioning 7 3 1 Checking the operating pressure topping up the heating water and venting the system 7 3 1 1 Checking the operating pressure 7 3 1 2 Topping up...

Page 3: ... sources of ignition of any kind Warn all occupants in the building but do not ring doorbells If you can actually hear gas escaping leave the building immediately Prevent third parties from entering and notify police and fire brigade from outside the building From outside the building call your gas supplier and licensed contractor H Danger if you smell flue gas Switch off the boiler Open windows a...

Page 4: ...ed danger H Danger of water damage Intheeventofsevereriskofflooding shutdownthe power and fuel supply to the device before water enters the installation location Never use the device if any part of it has been under water Immediately get in touch with a qualified service technician to have the device inspected and have any part of the control system and any air gas ratio control valves that have b...

Page 5: ...nger 2 3 1 Product information The main components of the Logano plus GB402 are Control unit not included in scope of delivery Boiler block Appliance frame and casing Gas burner The control unit monitors and controls all electrical components of the floor standing boiler The boiler block transfers the heat generated by the burner to the heating water The thermal insulation reduces the radiation an...

Page 6: ...front panel 2 Air gas ratio control valve 3 Control unit shown for illustration purposes Logamatic 5313or 8313 4 Gas burner with burner rod 5 Boiler block with thermal insulation 6 Boiler casing 7 Differential pressure switch 8 Condensation catch pan and siphon 9 Burner control unit 0010018751 001 1 2 3 4 5 6 8 9 7 ...

Page 7: ...sses When topping up a hot boiler with cold heating water thermal stresses can lead to cracking due to internal stress Only fill the heating system when cold Maximum flow temperature 40 C NOTICE System damage due to frequent topping up If you have to top up the heating water frequently the heating system maysufferdamagethroughcorrosionorscaling dependingonthewater quality Ask a certified heating c...

Page 8: ... maintain a high level of efficiency and to operate the heating system economically low fuel consumption To achieve a high level of operational reliability To maintain the cleanest possible combustion NOTICE Material damage due to a lack of or incorrect cleaning and service Have the heating system inspected maintained and cleaned once a year by a certified heating contractor We recommend you enter...

Page 9: ...c devices that are no longer serviceable must be collected separately and sent for environmentallycompatiblerecycling inaccordancewith the European Waste Electrical and Electronic Equipment Directive To dispose of old electrical or electronic devices you should use the return and collection systems put in place in the country concerned Batteries must not be disposed together with your household wa...

Page 10: ......

Page 11: ......

Page 12: ...Buderus Cotswold Way Warndon Worcester WR4 9SW All Enquiries 0330 123 3004 www buderus co uk In the UK and IE Buderus is a brand name of Bosch Thermotechnology Ltd ...