Quick Start Guide
4
EC Declaration of Conformity
We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the
product
PHD Pro2
is manufactured in conformity with the following directives:
2014/30/EU
,
2014/35/EU
and
2015/863/EU.
Date: 01/07/2021
Authorised by:
J P Hoveman
CEO, Buckleys (UVRAL) Ltd.
UKCA Declaration of Conformity
We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the
product
PHD Pro2 Pro2
is manufactured in conformity with the following UK legislation:
Electronic
Compatibility Regulations 2016
,
The Electrical Equipment (Safety) Regulations 2016
and
Restriction of the
Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
.
Date: 01/07/2021
Authorised by:
J P Hoveman
CEO, Buckleys (UVRAL) Ltd.
Specifications
•
Output voltage range:
6kV models:
500V - 6kV
30kV models:
0.9kV - 30kV
40kV models:
0.9kV - 40kV
•
Max. output current: <1mA (continuous)
•
Alarm sensitivity range: 10μA to 450μA
(factory-set to 20
0μA)
•
Recommended coating thickness range
(using NACE SP0274)
:
6kV models
: 4μm
-
576μm
30kV models : 13
μm
- 14.4mm
40kV models : 13
μm
- 25.6mm
•
Built-in test standard compliance: NACE
SP0274/ NACE SP0490/NACE SP0180/ASTM
D5172/ASTM G62/ISO 21809-2
†
Output voltage range:
•
Unit: 1.64kg, 172mm x 85mm x 235mm
•
Handle: 720g, 290mm x 85mm
•
When packed:
Dimensions:
Weight:
Basic kit:
580 x 440 x 250mm 9.4kg
Standard/Pipeline kit: 580 x 440 x 250mm 11.4kg
Complete kit:
510 x 250 x 630mm 13.6kg
•
Battery type: 4 x D-cell/LR20
•
Meter accuracy: <10kV: +/- 10V. >=10kV +/-
100V
•
Current meter FSD:
450μA
•
Maximum relative humidity: 80% non-
condensing
•
Working altitude: <2000m
•
Temperature range: 0ºC - +40ºC
Model
Low Range
Increment
High Range
Increment
Polarity
Battery Life
PHD Pro2 (6kV)
500V-6kV
10V
N/A
N/A
Positive
16 hours
PHD Pro2 (30kV)
0.9kV-10kV
10V
10.1kV-
3
0kV
100V
Positive
10 hours
PHD Pro2 (40kV)
0.9kV-10kV
10V
10.1kV-40kV
100V
Positive
8 hours
Note:
Due to ongoing technical developments, all stated information is typical and is subject to change without notice or obligation.
* Test conducted in accordance with BS EN50356. Test units fitted with 10,000mAh NiMH rechargeable cells. Instrument output voltage set
to maximum.
† These standards are pre-programmed and are provided for convenience. However, it is the user’s responsibility to ensure that the
correct settings are chosen for the intended application of this unit.