Technical data
Control of MOBILE DCU, PSU, DCU PSU
Voltage supply
>
33
300−I−9052003−EN−04/07.2021
4.3
Control of MOBILE DCU, PSU, DCU PSU
The MOBILE device is controlled via the X31 terminal.
20
14
8
1
EMDAG020c
4.3.1
Voltage supply
Voltage supply (KL30)
LV on−board supply system
12 V
24 V
Supply voltage TRM30
Rated voltage
V DC
12
24
Voltage range
V DC
10 ... 36
10 ... 36
Absolute voltage
(Pulse forms: ISO 16750−2)
(Behaviour: ISO 16750−1)
Min.
V DC
6
6
Max.
V DC
60
60
Current consumption
A
1 ... 2.5
0.5 ... 1.3
Quiescent current at T
amb
= 25 °C
m
A
40 ... 60
40 ... 60
Switch on/off device TRM15
Switching threshold
V DC
8
8
Current consumption
mA
1.7
1.7
4.3.2
Digital inputs
Digital inputs (FLX_IN)
LV on−board supply system
12 V
24 V
Rated input voltage
V DC
12
24
Voltage range
V DC
8 ... 36
8 ... 36
Digital HIGH
V DC
7.8 ... 9
15.6 ... 18.2
Digital LOW
V DC
3 ... 4.5
6.2 ... 8.8
Hysteresis
V DC
3.3 ... 6
6.8 ... 12
Input resistance
k
W
4.75
Reference potential
TRM31
Diagnostics option
Wire breakage/short circuit
Digital frequency inputs FLX_IN3, FLX_IN4
Frequency range
kHz
0 ... 10
Response time
m
s
90
Analog inputs FLX_IN1, FLX_IN2
Input frequency
Hz
0 ... 500
Resolution
Bit
12
Pull−up resistor or pull−down resistor
W
4.75
connectable/parameterizable
Summary of Contents for EMD G 0 Series