Configuration
The device must be configured. The configuration can be performed in two ways :
Mode 1 - with physical configurator connection
Mode 2 -
using a PC with the specific software, which can be downloaded free
of charge from www.homesystems-legrandgroup.com; this mode has the
advantage of offering many more options when compared with the physical
configuration.
Mode 1
Mod 1 requires the physical connection of the configurators to their sockets
P - entrance panel number
The configurator in socket P of the speaker module assigns to this a recognition number
inside the system. The numbering of the entrance panels must always start from P=0.
The entrance panel configured with P=0 must be a common (or main) entrance panel.
N - call number
Assigns the correspondence between the entrance panel pushbuttons and the audio
handsets or video handsets.
In common entrance panels made using pushbutton modules, 1 must be inserted in N of
the speaker module. The number of the first riser handset must be inserted in the local
entrance panels.
S - type of call signal
The configuration of S determines the call tone of handsets.
One can thus differentiate the calls from different entrance panels.
For the Classe 100 and Classe 300 handsets,
S
associates the entrance panel to the bell
programmed in the handset. It is possible to chose between 16 different preset bells.
For the SPRINT L2 handsets,
S
sets the call ringtone, according to the following table:
Configurator
0
1
2
3
Type of bell
2-tone
2-tone
2-tone
One-tone
1200 Hz
1200 Hz
1200 Hz
1200 Hz
600 Hz
0 Hz
2400 Hz
In one-family systems S=9 to configure the general call.
T - door lock relay timing
Configurator number
0=no configurator
1
2
3
4*
5
6
7
4 sec
1 sec
2 sec
3 sec
as
pushbutt.
6 sec
8 sec
10 sec
*Operation as pushbutton for 10 sec. max after which standby mode is activated.
To extend operation time over 10 seconds, use actuator item 346210 configured
with MOD=5.
M - enabling/disabling of call tones and door lock release tones, and management
of night backlighting always ON
The M configurations gives the possibility of managing the entrance panel call and door
lock release tones. It also gives the possibility of enabling night backlighting always ON
(light sensor disabled) according to the following table:
Configurator
M=0
M=1
M=2
M=3
Tone status
All tones
enabled
Door lock tone
disabled
Call tone
disabled
All tones
disabled
Configurator
M=4
M=5
M=6
M=7
Backlighting status
All tones
enabled
+
backlighting
always ON
Door lock tone
disabled
+
backlighting
always ON
Call tone
disabled
+
backlighting
always ON
All tones
disabled
+
backlighting
always ON
J1 - activation of call pushbutton columns
The J1 configurator gives the possibility of managing the Call pushbuttons of the speaker
module as follows:
J1 CONNECTED
= Only the right pushbutton column is enabled
J1 DISCONNECTED
= Both pushbutton columns are enabled (right + left)
J2 - additional EP power supply
Configurator J2 gives the possibility of enabling the additional power supply (1-2) of the
speaker module in the following mode :
J2 CONNECTED
= Additional power supply disabled
J2 DISCONNECTED
= Additional power supply enabled