Assembly, installation

The device can be installed flush mounted on the ceiling using the claws provided or a box 

for plasterboard or masonry ceilings, or as a ceiling fixture using the surface mounting box.

The Switch Sensor should never be installed close to sources of heat or the split units of air-

conditioning systems.

Ceiling sensor switch PIR+US IP20

EN

• BMSO4003: simplified configuration tool

• BMSO4001: advanced configuration tool

When the sensor receives an IR command via the configuration tool it emits a beep to 

confirm acquisition of the change.

For further information on the parameters see the technical specifications of configuration 

tool BMSO4001.

Restore factory settings:

1) Press LEARN briefly, the LED will flash slowly.

2) Press LEARN and keep pressed for 10 seconds until the LED flashes rapidly.

Changing the parameters with the configuration tool

Summary of Contents for BMSA2202

Page 1: ... area of coverage Used in environments where obstacles are present Lighting sensor Detects the lighting level of the environment and activates deactivates the load according to whetherthethresholdlightingvaluesetonthesensor canbemodifiedbytheuser islower higher than the value detected To prevent continual activation deactivation a tolerance of the threshold values is provided for Technical Data Po...

Page 2: ...means of the configuration tool BMSO4001 or BMSO4003 Using the two way IR receiver BMSO4001 with display it is possible to acquire the Switch Sensor parameters and memorise a set of adjustments to be applied on several devices Without cover when installed in flush mounting box With cover when installed without flush mounting box PIR detection US detection Low sensitivity 25 Mean sensitivity 50 Ø m...

Page 3: ...inglevel Walkthrough Ifapresenceisdetectedforaperiodoflessthan20sthesensorreducesthetimedelay setto3minutes Ifthetimedelaysetisalreadylessthan3minutes itremainsasis Eco Theloadisactivatedmanuallywhiledeactivationisautomatic ifnopresenceisdetectedattheendofthetimedelayset Followingdeactivationoftheload ifapresenceisdetectedwithin30s theloadis reactivatedautomatically retriggerfunctionactivated Atth...

Page 4: ...ture using the surface mounting box The Switch Sensor should never be installed close to sources of heat or the split units of air conditioning systems Ceiling sensor switch PIR US IP20 EN BMSO4003 simplifiedconfigurationtool BMSO4001 advancedconfigurationtool WhenthesensorreceivesanIRcommandviatheconfigurationtoolitemitsabeepto confirmacquisitionofthechange Forfurtherinformationontheparameterssee...

Page 5: ...ith use of a manual ON OFF command of the load ECO mode 100 m max 100 m max Ceiling sensor switch PIR US IP20 EN Standards Certifications Trademarks Directive Low voltage directive 2006 95 EC Electromagnetic compatibility directive 2004 108 EC Installation standard IEC 64 8 Product standard IEC 60669 2 1 EN 50428 Environmental standards EUDirective2002 96 EC WEEE Disposalofwasteelectricalandelectr...

Reviews: