background image

Installation manual

349311

349312

Video Display

Par

t. U3709UK

A - 11/08-01 PC

Summary of Contents for Axolute 349311

Page 1: ...Installation manual 349311 349312 Video Display Part U3709UKA 11 08 01 PC ...

Page 2: ......

Page 3: ...W 8 3 INSTALLATION 9 3 1 Installation with flush mounted box 9 4 QUICK CONFIGURATION 10 5 ADVANCED CONFIGURATION 13 5 1 FLEXIBILITY IN COMPOSITION 13 5 2 CUSTOMISATION OF TEXTS 14 5 3 OTHER FUNCTIONALITIES 15 5 4 CONNECTION TO THE PC 16 6 SETTINGS 17 6 1 CONFIGURATION MENU 18 6 1 1 OPTIONS 19 6 1 2 HANDSET CONFIGURATION 20 6 1 3 RESET 21 7 TROUBLE SHOOTING 22 7 1 PUSH TO TALK MODE 23 8 APPENDIX 24...

Page 4: ...led in the case of negligence incorrect use and tampering by unauthorised people Thus the Axolute Video Display must only be installed indoors must not be exposed to drips or splashes of water must only be used on BTicino digital 2 wire video door entry systems 1 2 PACKAGE CONTENT The package contains Axolute Video Display Installation Manual User Manual CD ...

Page 5: ...OM intercom call to an audio handset CAMERA direct activation of the camera associated to the entrance panel or separate for video CCTV ACTIVATION direct activation of the actuator associated to the entrance panel SEQUENTIAL SWITCHING sequential activation of the cameras in the system Scenarios Can activate the first five scenarios saved in the scenario module Alarms Candisplaythedividedzones thes...

Page 6: ...eaker 3 Call bell exclusion LED 4 Connection key activates deactivates the sound connection 5 Connection LED 6 Switch ON entrance panel and cycling key 7 Door lock LED 8 Door lock key activates the electric door lock of the associated or connected entrance panel 9 Navigation keypad navigates inside the menus confirms OK key or cancels C key the programming operations 10 Microphone 1 4 8 3 5 7 10 2...

Page 7: ...nel at rest that of the associated Entrance Panel The LED signals its operation Activation Entrance Panel Cycling Activates the switching ON of the associated Entrance Panel and cycles any other Entrance Panels cameras key Gives access to the menu confirms the selection made key Inside the menus change the value set In audio video connection allow quick access to the audio video adjustments keys I...

Page 8: ...CRIPTION N P M BUS 1 2 OFF ON AXOLUTE 2 4 5 3 1 1 Mini USB connector for connection to the PC 2 Configurator socket 3 Connection to the Bticino 2 wire digital system BUS 4 Stretch end ON OFF microswitch 5 Connector for extra power supply ...

Page 9: ...lute Video Display use a flush mounted box item 506E After making all the connections fasten the Axolute Video Display to the flush mounted box being careful to arrange the wires so that they are not damaged Finish the installation with the cover plate in the version required ...

Page 10: ...ation is recommended for standard video door entry systems where no special functions are required and short installation times are important In this case the device is configured physically inserting the configurators in sockets N P and M The configurator in M defines the video door entry mode corresponding to a predefined set of five video door entry functions Quick configuration by means of M c...

Page 11: ...ich can be selected with M 0 6 4 QUICK CONFIGURATION M 0 M 1 M 2 M 3 M 4 M 5 The main menu page always has the five selected functions plus SETTINGS which goes to a page dedicated to the device settings and configurations INTERCOMMUNICATING I INTERCOMMUNICATING I CAMERA I ACTIVATION I CAMERA I CAMERA I ACTIVATION I ...

Page 12: ...ed by a number equal to that indicated by the icon selected e g CAMERA 2 activates the camera with address P 2 ACTIVATION activation of the actuator with the same address as the associated Entrance Panel increased by a number equal to that indicated by the icon selected e g ACTIVATION 3 opening of the Entrance Panel door lock configured with P 3 directly without the call or activation of actuator ...

Page 13: ...ts Other ways of managing the house automation systems the call to a second level page containing mixed functions can be entered enter the PROFESSIONAL STUDIO HANDSFREE PAGING and MULTIMEDIA commands which otherwise can only be called from the SETTINGS menu in the first page or in a second level page 5 ADVANCED CONFIGURATION 5 1 FLEXIBILITY IN COMPOSITION the first page can be written with the fun...

Page 14: ...or the following systems ALARMS customise the messages associating a descriptive text to the zone where the alarm comes from change the channel combination type of alarm 5 ADVANCED CONFIGURATION TEMPERATURE CONTROL customise the description of 10 system zones SOUND SYSTEM customise the description of 6 Rooms Amplification sound points customise the description of 4 sources BEDROOM DRAWING CD KITCH...

Page 15: ... SYSTEM can select and control up to 6 Rooms Amplification sound points specifying the address wanted can select and control up to 4 Sources specifying the address wanted TEMPERATURE CONTROL select and control up to 10 system zones specifying the address wanted In the example at the side 12 communication functions and 18 scenarios can be entered 5 ADVANCED CONFIGURATION COMMUNICATION INTERCOMMUNIC...

Page 16: ...eo Display must be powered and not physically configured 5 4 CONNECTION TO THE PC To transfer the configuration made with the TiAxoluteDisplay software or update the firmware connect to the Axolute Video Display to the PC using USB miniUSB cable 5 ADVANCED CONFIGURATION BUS ...

Page 17: ... the SETTINGS menu 6 SETTINGS CONFIGURATION ADJUSTMENT SERVICES MESSAGGES BELLS INFORMATION For information about these menuspleaseconsulttheUser Manual in the CD enclosed AREA RESERVED FOR CONFIGURATION OF THE DEVICE WARNING OPTIONS PARAMETER MODE H CONFIGURATION RESET SETTINGS SETTINGS CONFIGURATION ...

Page 18: ...ETTINGS Select CONFIGURATION Press OK to confirm Select SETTINGS Press OK to confirm Select CONTINUE Press OK to confirm Select QUIT Press OK to quit WARNING AREA RESERVED FOR CONFIGURATION OF THE DEVICE QUIT CONTINUE WARNING AREA RESERVED FOR CONFIGURATION OF THE DEVICE QUIT CONTINUE SETTINGS CONFIGURATION ...

Page 19: ... to transmit the paging call Press C to return to the next page 6 1 1 OPTIONS On selecting OPTIONS access is possible to the following system settings 6 SETTINGS Select OPTIONS Press OK to confirm Select e g SLAVE Select NO YES Press OK to confirm Select DEFAULT to return to the factory settings all NO OPTIONS PARAMETER MODE H CONFIGURATION RESET SLAVE NO PAGING NO DEFAULT SLAVE NO PAGING NO DEFAU...

Page 20: ...ntrance Panel P can be edited 6 SETTINGS Select H CONFIGURATION Press OK to confirm Select CONFIRM Press OK to confirm Press OK to confirm Select ADDRESS N and or P Select CONFIRM Set the address OPTIONS PARAMETER MODE H CONFIGURATION RESET H CONFIGURATION ADDRESS N 01 ADDRESS P 00 CONFIRM H CONFIGURATION ADDRESS N 01 ADDRESS P 00 CONFIRM ...

Page 21: ... settings 6 SETTINGS Select RESET Press OK to confirm Press C to return to the previous page Press OK to quit the menu Select CONTINUE to cancel the device configuration Press OK to confirm OPTIONS PARAMETER MODE H CONFIGURATION RESET CANCEL THE CONFIGURATION OF THE DEVICE QUIT CONTINUE CANCEL THE CONFIGURATION OF THE DEVICE QUIT CONTINUE ...

Page 22: ...gain When called the handset does not ring check that the handset and entrance panel have been correctly wired and configured check that the Call Exclusion function is not active or that the bell volume has not been zeroed When called the handset rings but the monitor does not switch on check that it has not been set as Slave At the entrance panel it is difficult to hear the caller talk at a maxim...

Page 23: ...alk to the entrance panel The LED remains ON Release the key to hear from the entrance panel The LED becomes red To end the connection press the connection key briefly The LED goes out Receiving a call from the entrance panel Press the Connection key to answer the call The LED is ON 7 1 PUSH TO TALK MODE 7 TROUBLE SHOOTING ...

Page 24: ...24 Video Display TECHNICAL DATA 8 APPENDIX from SCS bus 18 28 V from 1 2 18 28 V 200 mA in A V connection 8 mA in stand by Operating temperature 0 40 C Power supply Absorption Max ...

Page 25: ...25 9 MEMO CARD NOTES ...

Page 26: ...26 Video Display 9 MEMO CARD NOTES ...

Page 27: ......

Page 28: ...SpA reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same BTicino SpA Via Messina 38 20154 Milano Italy www bticino it ...

Reviews: