![background image](http://html1.mh-extra.com/html/bticino/374001-03/374001-03_user-and-installation-manual_2825436010.webp)
Entrance Panel keyboard 4.3"
User and installation manual
10
Connection clamps
GND
Lif
t C
on
tr
ol
system common ground
terminal for RS485 connection
FIRE Linkage – GND
local door lock release
pushbutton connection for
firealarm system
RS485B
terminal A
Door OPEN – GND local door lock release
pushbutton connection
RS485A
terminal B
+12V – GND OPEN access control devices power
supply
-
additional power supply
clamps
OPEN
third party access control signal
input for door lock opening
(+12Vdc pulse)
+
GND
system common ground
terminal for third party
connection
NC
interlocked contact
SENSE
door lock status signal input
(dry contact)
C
LOCK+
electric door lock connection
and control
(12V - 4A impulsive on 3 Ohm
maximum)
NO
LOCK-
Summary of Contents for 374001/03