background image

346310

Switchboard

Installer manual

0

1

G

F

-1

1

W

0

1

Summary of Contents for 346310

Page 1: ...346310 Switchboard Installer manual 01GF 11W01 ...

Page 2: ...2 ...

Page 3: ...ry system function keys 7 2 4 Navigation keys 7 2 5 Back view 8 3 Installation 9 4 Settings 10 4 1 Handset IU D N 12 Function 12 4 2 Slave handset IU 13 4 3 Modify contact 14 4 4 Time bands 17 4 5 Automations 18 4 6 Function Key Setup 19 4 7 Alarm Setup 20 4 8 Configuration 21 4 9 Change password 24 5 Advanced configuration 25 5 1 Connection to the PC 25 6 Troubleshooting 26 7 Appendix 27 ...

Page 4: ...ally become void in case of negligence improper use tampering by unauthorised personnel Therefore the Switchboard must only be installed indoors must be kept away from water drips and sprays must only be used in conjunction with BTicino 2 wire digital video door entry systems 1 2 What s in your box In your box you will find Switchboard CD with the manuals 1 Introduction ...

Page 5: ...the switchboard functions during certain time bands which can also be set by the user a CALL LIST saving all the unanswered calls received from apartment handsets an HANDSET DIRECTORY and an ENTRANCE PANEL DIRECTORY Their programming ensures easy identification of the calling apartment or entrance panel INTEGRATIONS Communication From the main menu screen it is possible to access a range of video ...

Page 6: ...from other cameras 3 Handsfree microphone 4 Navigation key it s used to navigate through the menu and confirm the selections made OK key 5 Cancel key 6 Direct call key 7 Door lock key 8 Directory key 9 Entrance panel activation and cycling key 10 Handsfree key 11 Active alarm LED 12 Switchboard status LED 13 Alphanumeric keypad 14 Configurable function keypad 15 Handsfree loudspeaker ...

Page 7: ...ory screen Entrance Panel Cycle mode activation It switches the associated Entrance Panel on and enables cycling through any other Entrance Panels or cameras present Handsfree key It activates the handsfree mode excluding the handset or vice versa 2 4 Navigation keys OK key It switches the monitor on It provides access to the menu it confirms the selection made Keys They can be used to scroll hori...

Page 8: ...5 Back view 1 Mini USB connector for connection to the PC 2 End of line ON OFF micro switch 3 Connection to the BTicino 2 wire digital system BUS 4 Additional power supply connector 1 2 5 Optional siren contact connector ...

Page 9: ...chboard Installer manual 9 3 Installation 1 Remove the cover from the base 2 Insert the cable in the appropriate slot 3 Connect to the bus and to the additional power supply if required 4 Replace the cover ...

Page 10: ...g the switchboard press After connecting and powering the switchboard press to select the desired functions and press OK to confirm OK For a detailed description of all functions refer to the user manual that can be found in the CD supplied Use the configuration icon to access to the installation setup menu This menu is password pro tected and can only be accessed by the installer WARNING Wrong ac...

Page 11: ...he keypad default password 12345 P a s s w o r d The following icon screen appears 1 Handset IU D N function 2 Slave handset IU 3 Modify contact 4 Time bands 5 Automations 6 Function key setup 7 Alarm setup 8 Configuration 9 Change password D N I U F u n c t i o n 1 7 8 9 4 2 3 5 6 ...

Page 12: ...d to enable or disable the handset Day Night function Press OK repeatedly to enable disable OK the D N function Select the handset D N function E n a b l e d D N I U F u n c t i o n Press to exit the menu Press OK to access the menu OK D N I U F u n c t i o n ...

Page 13: ...OK to access the menu OK Select the slave handset function To enable or disable the slave handset E n a b l e d S l a v e I U A d d r e s s S l a v e I U A d d r e s s 0 S e r v i c e I U Press OK repeatedly to make OK the selection Press OK to highlight the value to change Press OK to confirm OK To change the address Change the value Select the desired position Select the desired position Press t...

Page 14: ... h a n g e C o n t a c t 4 3 Modify contact It can be used to create change or delete the contacts in the various directories Select the Modify Contact function Press OK to access the menu OK PressOKrepeatedlytoselectthedesired OK directory Select the desired action Create Modify Delete Press OK to confirm OK 4 Settings ...

Page 15: ...hlight data for which the OK value must be entered Use the keypad to enter the new value or description Use the keypad to enter the new value or description Move the cursor to the existing parame ters in succession Selecttheparameterthatneedschanging and press OK Move the cursor to Save Once the necessary details have been entered move the cursor to Save Cancel the entry in case of mistake Press O...

Page 16: ...t 3 3 A p a r t m e n t 4 4 A p a r t m e n t 5 5 A p a r t m e n t 6 6 A p a r t m e n t 7 7 Delete Press OK to delete the contact OK Move the cursor to the contact to delete Press to exit the menu WARNING The switchboard makes direct calls using the logic addresses ...

Page 17: ...rm and con OK tinue with the subsequent time bands Press OK to display the screen used to OK enter the time bands Select the Time Bands function Select Weekday to set the time bands for every day from Monday to Friday at the same time Use the keypad to enter the desired time use the Use the keypad to enter the desired key to delete wrong entries Press OK twice to delete the selected time band and ...

Page 18: ...alls are active from the entrance panel Press OK to access the menu OK Select the Automation function L o c k C o n f i g u r a t i o n S C S A d d r D e s c r i p t i o n R i s e r 1 M a i n E P 0 2 1 3 1 4 1 5 1 Press OK to highlight the entry field Use the keypad to enter the desired value or description Press OK to confirm OK Press to exit the menu 4 Settings ...

Page 19: ... Night Presence status Slave handset Staircase light Handset Call Entrance panel Call Switchboard call ______________ not configured Press OK to access the menu Select Function Keys Setup F u n c t i o n K e y S e t u p K e y S e t u p F 1 F u n c t i o n D o o r l o c k 1 d o o r 1 S C S A d d r 6 R i s e r 6 Press OK repeatedly to se lect the key to configure F1 to F12 PressOK repeatedlytoselect...

Page 20: ...ftheswitchboard Press OK to access the menu OK Press OK repeatedly to enable disable OK the function Select the Alarm Setup function Select the desired item A l a r m s E n a b l e d E n a b l e d S i r e n Press to exit the menu A l a r m s S e t u p NOTE The alarm function can also be enabled during the day only WARNING Alarms can only be managed from the main switchboard local address 0 ...

Page 21: ...ype selection type 1 alphanumeric type 2 coding BPI selection of the navigation language Press to access the menu Press OK to confirm OK Select the Configuration functions To change the local address of the main EP Select Local address A s s o c i a t e d C a m e r a A c t i v a t e d A l p h a n u m e r i c A d d r e s s B o o k E n g l i s h L o c a l A d d r e s s A s s o c i a t e d E P L i s ...

Page 22: ...nlyoneforeachsystem or secondary local address 1 to 15 In this case enter the address of the associated primary switchboard in the appropriate field A s s o c i a t e d C a m e r a A c t i v a t e d A l p h a n u m e r i c A d d r e s s B o o k E n g l i s h L o c a l A d d r e s s A s s o c i a t e d E P L i s t Press OK to confirm OK Select Associated EP List For the list of the associated Entra...

Page 23: ...anguage Press to exit the menu Press OK to confirm OK Press OK to confirm OK Press OK repeatedly to move OK the cursor to the desired EP Move the cursor to the SCS address line Press to exit the menu Press OK to highlight the value to change Use the keypad to enter the value Select the desired item Directory type Alphanumeric for each contact the content of the Description field will be displayed ...

Page 24: ...word is 12345 Press OK to confirm OK Select the Change Password function Press OK to confirm and exit the menu OK Enter the new password using the keypad max 5 digit number Press Enter the new password using the keypad max repeatedly to delete entries made C h a n g e P a s s w o r d N e w P a s s w o r d 1 N e w P a s s w o r d S t o r e d ...

Page 25: ... in the CD supplied WARNING Some functions like the creation of the directories and the management of the bells can only be performed using the software 5 1 Connection to the PC To transfer the configuration performed using the TiSwitchBoardDevice software or to update the Firmware connect the switchboard to the PC using an USB miniUSB cable To enable communication the switchboard must be powered ...

Page 26: ...ed when the Door Lock key is pressed check that the switchboard is correctly wired and configured The switchboard does not ring check that the switchboard is correctly wired and configured check that the bell volume has not been turned right down From the entrance panel it is difficult to hear who is speaking speak at a maximum distance of 50 cm from the handsfree microphone reduce the volume of t...

Page 27: ...ption Max from BUS without additional power supply 450 mA A V connection at the minimum operating voltage 35 mA in stand by Operating temperature 0 40 C Absorption Max from 1 2 300 mA Note about the LCD screen The LCD screen has been produced using state of the art high precision technology It may however happen that up to 5 small black and or red blue or green dots will appear on the LCD screen T...

Page 28: ...pA reserves at any time the right to modify the contents of this booklet and to communicate in any form and modality the changes brought to the same BTicino SpA Via Messina 38 20154 Milano Italy www bticino com ...