![BTI Espirit Series Operating Manual Download Page 4](http://html.mh-extra.com/html/bti/espirit-series/espirit-series_operating-manual_2825050004.webp)
Ph: 905.636.9865 Fax: 905.636.9879
E-mail:
Website:
www.bti-chargers.com
4
Note that the output current and/or voltage and battery type setting may have been adjusted
on your unit. Refer to the OPERATION details above to confirm the settings.
If the battery type setting is changed, it is recommended that this is noted on the front label.
Before changing battery type setting, be sure to check the relevant BTI technical documents
that match the serial number range of your charger.
A
sample
product rating label is below.
TECHNICAL DATA
AC Input voltage range: 115V AC +/- 10%, 50-60Hz
AC current input: 4.3A max.
AC fuse: 6.3A
Efficiency:
>
80%
Output ripple at max load <150mV.
Accuracy of power and voltage measurements 1%.
Thermal protection against overheating.
ISO isolation transformer, class H
Operating
temperature:
-10
o
C to +45
o
C (14
o
F to 113
o
F)
Storage
temperature:
-40
o
C to +45
o
C (-40
o
F to 113
o
F)
Relative humidity range: 0 – 80%
REGULATORY AND COMPLIANCE
The
Esprit Series
chargers are CSA Listed:
CAN/CSA-C22.2 No 107.2 and UL 1236
The
Esprit Series
are CE compliant.
The tests of electromagnetic compatibility (EMC) on these devices were carried out in
compliance with the CEI EN55014-1+A2(04/98-06/99) and CEI EN 55014-2(10/98)
STANDARD norms, with the test instructions and conditions as requested by the norms.
NORM
RESULT
EN 55014-1+A2
COMPLIANT
EN 55014-1
COMPLIANT
EN 61000– 3-2 COMPLIANT
EN 61000– 3-3
COMPLIANT
EN 61000– 4-2
COMPLIANT
EN 61000– 4-4
COMPLIANT
EN 61000– 4-5 COMPLIANT
EN 61000– 4-6
COMPLIANT
EN 61000– 4-11 COMPLIANT
Regarding immunity, these chargers are classified as Category II.
The
Esprit Series
chargers do not emit radio frequencies.
V2.0
November 01, 2020 – starting serial number 2551000