Ph: 905.636.9865 Fax: 905.636.9879
Web:
www.bti-chargers.com
7
AC POWER CONNECTION
This charger is cULus Listed. Units may be supplied without an AC cord or AC plug. Supply of
an appropriate AC cable and plug for connection to AC must to be performed only by qualified
personnel.
It is essential to connect the charger to a mains supply of standards corresponding to the power
of the battery charger installed.
THREE PHASE 200/208/220/400/480 VAC
Make sure to earth the charger properly where relevant using minimum AWG10 wire.
Note the internal label showing the connection order of the power cord conductors:
(EMPTY, LINE1, LINE2, LINE3, GROUND)
REPAIRS
Repairs must only be carried out by qualified personel.
Use only original type parts for repairs.
ELECTROMAGNETIC COMPATIBILITY
This battery charger complies with the following standards:
EN 55014-1 (Emission)
EN 55014-2+A1+A2 Immunity – Category II)
EN 61000-3-2 (Harmonic Current Emission)
EN 6100-3-3 (Voltage Fluctuation and Flicker)
WARNING!!!
Connect the mains conductors in the order
shown below:
USE WIRES SUITABLE FOR AT
LEAST 75 DEG C
LI L2 L3 PE