Appendix
© BTG 2019
User Manual CPM AX2066en Rev.B
33
5.2 HCM-8010 Connections
Connection Block
BT-5500
BLT-5500
DLT-5500
RET-25x2
RET-55xx
P1
DI3
Digital In 3
Initiate lab sample
Sample Input
Sample Input
Interlock
DO
Digital Out 1
Alarm Output
Alarm Output
Alarm Output or PCD-
1000 control
Alarm Output
P2
DI1
Digital In 1
Calibration set Input A
Calibration set Input A
Calibration set Input A
Calibration set Input A
DI2
Digital In 2
Calibration set Input B
Calibration set Input B
Calibration set Input B
Calibration set Input B
P3
AO
Analog Out 1
Channel 1 output value
4 - 20 mA
Dissolved lignin
(Channel 1) output value
4 - 20 mA
Total consistency
(Channel 1) output value
4 - 20 mA
Total consistency
(Channel 1) output value
4 - 20 mA
AI
Analog In1
Analog input signals
from external equipment
4 - 20 mA
Not used
Not used
Not used
P4
AO2
Analog Out 2
Channel 2 output value
4 - 20 mA
Total consistency
(Channel 2) output value
4 - 20 mA
Ash consistency
(Channel 2) output value
4 - 20 mA
Ash consistency
(Channel 2) output value
4 - 20 mA
(RET-55x3 only)
AO3
Analog Out 3
Channel 3 output value
4 - 20 mA
Not used
Not used
Not used
P5
AO4
Analog Out 4
Channel 4 output value
4 - 20 mA
Not used
Not used
Not used
AO5
Analog Out 5
Channel 5 output value
4 - 20 mA
P6
AI2
Analog In 2
Analog input signals
from external equipment
4 - 20 mA
Not used
Not used
Not used
AI3
Analog In 3
AI4
Analog In 4
P7
DI4
Digital In 4
Not used
Not used
Not used
Internally pre-wired
(a)
(a) For more information about internally pre-wired connections, see the installation drawing for the transmitter
DO2
Digital Out 2
P8
SV4
Sol. valve 4
Nut used
Not used
Not used
Internally pre-wired
(a)
SV5
Sol. valve 5
P9
SV1
Sol. valve 1
Not used
Not used
Not used
Internally pre-wired
(a)
SV2
Sol. valve 2
SV3
Sol. valve 3