14
T419S Indicator User Instructions
Operating Instructions
3 Operating Instructions
The T419S provides multiple tare memory, transaction counter and weight
accumulator.
3.1 Power Up
When the indicator is powered up, you will see the startup screen for the Accumulation
application, shown below:
3.2 Accumulation weighing application
Gross and net weighing are covered first below followed by the instructions for the
Accumulation app.
3.2.1 Gross weighing
To perform gross weighing, power up the unit and follow these steps:
1.
Empty the scale and, if necessary, press
ZERO
to zero the display …
0
is displayed and the
center-of-zero
annunciator lights.
2.
Place item to be weighed on the scale …
Weight is displayed.
3.
Repeat steps
and
.
SELECT key default function:
You can view the gross, net, tare, gross total, net
total, tare total and transaction total display values or other configured scale
parameters by repeatedly pressing
SELECT
.
kg
Gross
SETPT
CHAN
ID
ID: 0
0
Accum Chan: 1
Net Total: 0 lb
Transactions: 0
To change unit of measure, press
UNITS
.