Autolearn Mode  

The autolearn mode is enabled by default (position no. 0 is set in the 'proto' submenu). To 
disable it, the communication protocol must be set manually using the embedded user menu or 
the WagSet RM software.  
 
When autolearn mode is active, each time the device is started, it detects the parameters of the 
communication with the weighing terminal and analyses the structure of the data frames it 
sends. Then it adjusts the remote display's settings to enable correct communication with the 
terminal. The whole operation lasts several seconds, depending on the baud rate and the time 
intervals between consecutive frames. All remote display’s communication interfaces are 
supported, i.e. RS232/RS485/CL and Ethernet.  
 
The autolearn procedure is as follows:  
1. Baud rate detection - dot 1 flashing on the display  
2. Baud rate verification - dot 1 solid, dot 2 flashing  
3. Analysis of the protocol and its frame structure - dots 1 and 2 solid, dot 3 flashing  
 
During the analysis of the protocol and its frame structure, the measurement unit sent is also 
recognized. The following tags are recognized - "kg" 'K' " t" 'T' 't' " g" "gr" 'G' 'g' "lb" 'L' 'l' "oz" 'o' 
'O'. In case the terminal does not send a unit or sends a unit that is not recognized by the 
autolearn function, the default unit will be set to lb. 
 
The autolearn mode supports the following transmission parameters: 
 
Baud Rate 

2400, 4800, 9600, 19200 

Transmission parameters (data bits, parity, stop bits): 

8N1, 7E1, 7O1 

 

Note: If the data is sent via the Ethernet to the display and then one of the other interfaces, i.e. 
RS232 / RS485 / CL is connected - the autolearn procedure will be carried out again in order to 
determine the UART parameters and the protocol (the protocol for serial interfaces may differ 
from the Ethernet protocol). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 841-100040

Page 1: ...Page 1 BT 470 REMOTE DISPLAY Item 841 100040 841 100041 OPERATION SETUP GUIDE V1 6 ...

Page 2: ...Embedded User Menu 6 Factory Default 7 Connecting the Display to a Computer for Configuration Purposes 8 WagSet RM Windows Operating System only 8 Web Panel Configuration Method 9 Remote Display Connections 10 Ethernet Settings to Transmit Weight Data 10 Replacement Part Item Numbers 11 ...

Page 3: ...g languages EN PL RU DE CZ SK HU UA LT LV NO SE FR NL BR RO ES TR FI Changing the IP address and port of the weight indicator sending the data Default Indicator IP 192 168 1 12 sending data on port 2102 The detailed information concerning the display configuration from a PC can be found in the manual supplied with the WagSet RM software Click Help Help or press the F1 button The way of connecting ...

Page 4: ...mended to install in an area protected from direct sunlight and rain Item 841 100040 includes a visor and pole mounting hardware The kit included brackets for a 3 pole but other sizes can be purchased as needed Attach the Unistrut to the back of the visor then slide clamps into unistrut tighten the bolt to secure to the pole Then attach scoreboard to the visor selecting one of the three holes to a...

Page 5: ... rate detection dot 1 flashing on the display 2 Baud rate verification dot 1 solid dot 2 flashing 3 Analysis of the protocol and its frame structure dots 1 and 2 solid dot 3 flashing During the analysis of the protocol and its frame structure the measurement unit sent is also recognized The following tags are recognized kg K t T t g gr G g lb L l oz o O In case the terminal does not send a unit or...

Page 6: ...nfo proto custm or reset The option is entered after releasing the button when its name is being displayed If the button is released when the screen is blank between two consecutive options the display will return to its normal operation info option allows you to display the device software version and the network layer settings IP address network mask communication port for the WagSet RM software...

Page 7: ...ccording to the previously set parameters Uploading new network settings is possible using the WagSet RM software or via web panel Seq no Terminal name Protocol Seq no Terminal name Protocol 0 Autolearn function 28 CAS NT570A 1 Rhewa 83 Plus 29 Cardinal 825 2 Radwag 30 Cardinal 204 225 748P 3 HBM WE2108 31 AMCS Group 4 HBM WE2110 32 A D AD4329 AD4401 5 Rinstrum 320 420 Auto1 33 Ian Fellows SG0 6 S...

Page 8: ...TEK Serial String then Set Port settings can be changed under Basic If using ethernet to transmit your serial string go to Custom settings to set your indicator s IP address To display alpha characters download one of the configuration files on page 3 of this manual or select one of the B TEK strings in configuration Open the file then select the measurement result tab then select display under Di...

Page 9: ...5 Subnet mask 255 255 255 0 and confirm changes 3 Download Devicer 2 08 Devicer 2 08 Download 4 Open Devicer program then click the binocular icon to search 5 Double click the IP address of your scoreboard 6 When the web browser opens enter login admin pass dbps In the web browser network settings can be modified password can be changed not recommended Protocols can be selected Status information ...

Page 10: ... Weighing Terminals output B RS485 and RS422 interface inverting line Weighing Terminals output GND GND line of the RS485 and RS422 interfaces Not recommended for use at risk of a significant difference in ground potential of the display ground and weighing terminal ground Ethernet RJ45 RJ45 connector 110 230 VAC power supply L Phase conductor N Neutral conductor PE Protective conductor Ethernet S...

Page 11: ...TORS 841 500074 BT 470 4 7 VISOR 841 500075 BT 470 4 7 POLE MOUNT KIT 841 500076 2 POLE MOUNT BRACKETS ORDER TWO PER SCOREBOARD 841 500077 3 POLE MOUNT BRACKETS ORDER TWO PER SCOREBOARD 841 500078 4 POLE MOUNTBRACKETS ORDER TWO PER SCOREBOARD 841 500079 5 POLE MOUNTBRACKETS ORDER TWO PER SCOREBOARD 841 500080 BT 470 MAIN BOARD 1 841 500081 BT 470 DISPLAY BOARD 2 841 500082 BT 470 POWER SUPPLY BOAR...

Reviews: