background image

t

m

M

TALK MODE

MONITOR MODE

MUTE

Press

to go off-hook.

A double beep is heard and the mode LED flashes

.

Press

to go back on-hook. The mode LED then flashes

.

: if Tele300B is connected to an overvoltage or a digital signal,

then Tele300B does not loop the line and sounds an alarm.

Connect Tele300B to the line.
Press and release

to go off-hook. Thanks to

, there are four

different cases:
1\ a digital signal is present:

is heard, Tele300B locks out and

does not loop the line. To override this alarm, hold down the

key.

2\ a high DC level is present (>116V±4V):

is heard,

Tele300B locks out and does not loop the line. This alarm may not be
overridden.
3\ a dc level between 76V(±4V) and 116V(±4V) is present:
is heard, the mode LED flashes

, Tele300B locks out and

does not loop the line. To override this alarm, press

again.

4\ no alarm (i.e. no digital signal nor high DC present): Tele300B goes off-hook
and loops the line.

When connected to normal DC, it is possible to override the digital detection
lock-out by pressing and holding

for more than 6 seconds and until the

override tones have stopped. This can be particularly useful on a faulty line
being highly imbalanced.

Press

. The mode LED flashes

. Press again

to switch off Tele300B.
In order to extend its battery life, Monitor is automatically switched off after 20
minutes, if connected to a powered line, and 5 minutes after disconnection. An
audible signal is heard on timing out.

Press and release

to cut off transmission during a call. Press again to

talk.

300B

Press

to activate the speaker function. If

is pressed

while Tele300B is off, then Loud-speaker Monitor is automatically activated.

Press and release

to select the high setting, press again to return to

the normal setting.
In TALK mode, receive only is possible while in speaker mode.
After disconnection from the line for more than 5 minutes, Tele300B
automatically switches off and the time-out tone is heard.

t

m

t

t

t

t

m

m

M

s

s

v

TALK

RED

MONITOR

GREEN

TALK

a two tone alarm

TALK

a single tone alarm

a single tone alarm

RED and GREEN

TALK

Digital signal detection OVERRIDE

TALK

MONITOR

GREEN

MONITOR

MUTE

SPKR

SPKR

VOL

Press

and observe the polarity LED.

LED: red lead is connected to A (+Ve).

LED: red lead is connected to B(-Ve).

During this test, Tele

remains high impedance and will not interfere with

data or speech calls..

PLEASE NOTE

Volume adjustment:

AUTOMATIC PROTECTION OF DIGITAL LINES:

POL: POLARITY TEST

SPKR: SPEAKER MODE

(high impedance).

POL

RED
GREEN

P

s

P

DigAlert

TM

DigAlert

TM

l

f

S

r

p

LNR/PAUSE: Last Number Redial and Pause

FLASH

STO

MEM Storing a number in memory

Dialling a number from a memory location.

PULSE Dialing

Mixed Pulse and Tone dialling

LOW BATTERY

INSTALLING or REPLACING THE BATTERY

LNR/PAUSE

LNR/PAUSE

LNR/PAUSE

FLASH

STO

MEM

STO

MEM

PULSE

you are advised to

replace the battery as soon as possible

Press

immediately after off-hook to redial the previous

number dialled.

In STORE mode (see below) press

to

insert a Pause in a memory. If within the first 5 entries, this inserts a 2 second
pause in the dialling out string, if not, then it halts the dialling.

Press

to resume.

A timed line break is generated when this

button is pressed.

:

There are ten memory locations, one under each of the dialling digits.
While connected to a line and in TALK

mode:

Press

to enter STORE mode, Press

and a location (0-9).

Enter the telephone number to be stored then press

to store.

The number is stored under the button chosen. ln memory you may also store

,#,

Flash or

Pause. These will be redialled as they were entered.

While connected to a line and in TALK

mode:

Press

. Press the location digit 0-9.

The stored number under that button will be redialled.

With the DigAlert™ connected to a live line, press

before

selecting

Talk mode. This is confirmed by a single high beep. Dialling mode

will automatically revert to Tone when the line is disconnected or if the
Tele300B is switched off.

Select Pulse mode as above and dial the Pulse digits. Press

(Tone) then dial

the Tone digits (the star will not be dialled out). This will be stored in the Last
Number Redial memory (

) as dialled. Redialling will be mixed mode if in

Pulse mode when redial

is attempted. If tone mode is selected all digits

will be dialled in Tone including the star.

A red LED at the centre of the keypad starts to flash RED when the battery
needs replacing. Also, at each mode change of the Tele300B, a low battery
tone will be heard. Once the low battery LED is on, Tele300B will keep on
working to its specification for a couple of hours, but

.

Remove the three hatch cover screws as shown below. Unclip the battery and
replace it with a 9V alkaline battery. Make the change within one minute if you
want to retain your memory contents.

Disconnect from the line and press

Monitor button to extinguish the Green

(Mode) LED.

To cure it, disconnect the battery for at

least 2 minutes and short the terminals together for a few seconds (when
battery not fitted). Replace the hatch cover ensuring that the line cord is
correctly routed. Tighten the screws firmly but do not use excessive force.

l

l

l

f

t

S

r

S

* f

l

t

r

p

t

*

l

l

m

It is very important to ensure that Tele300B is off when replacing a battery
(No LED lit).

If you do not do this, when the new battery is fitted, the test-

telephone may not restart correctly.

?

1

2

3

4

5

6

7

8

9

0

#

Red: Talk Mode.
Green: Monitor mode.

Red lead polarity:
Green = B(-Ve).

= A (+Ve).

Red

Replace

Battery

PULSE

FLASH

VOL

MEM

LNR/PAUSE

STO

POL

SPKR

TONE

TALK

MONITOR

MUTE

Warning!

When in Loudspeaker mode,

hold loudspeaker more than 30cm (1 foot)
from your ear.

Misuse can result in hearing damage.