11- 6
Service Guide
LWE180, LWE200, LPE200, LPE240
© BT Europe AB
Hydraulic/Pneumatik – 6000 LWE 180/200 LPE 200
Adjusting the pressure limit valve
T-code
Valid from serial number
Date
Order number
660, 661, 662, 497
723984-
2005-05-11
225553-040
11.6 Adjusting the pressure limit valve
The pressure limit valve is set to the correct value at the factory, but
may need to be adjusted if the valve or the complete hydraulic unit is
replaced.
The truck should be capable of lifting a load of between 2050-2100 kg.
1.
Locking nut.
2.
Adjuster screw, pressure limit.
Adjusting clockwise results in increased pressure.
Adjusting anticlockwise results in decreased pressure.
•
Loosen the locking nut (1) using a 13 mm spanner.
•
Place a load of 2000 kg on the forks and check that the truck can lift
it.
•
If the truck lifts 2000 kg, place a further 100 kg on the forks. Check
whether the truck can lift the load.
•
If the truck lifts 2100 kg, adjust the pressure limit by turning the ad-
juster screw (2) anticlockwise using a 4 mm allen key until the truck
cannot lift the load.