User/Installation Guide

(Non roaming version)

5G GSM STU

Summary of Contents for 5G GSM STU

Page 1: ...User Installation Guide Non roaming version 5G GSM STU...

Page 2: ...over a Redcare enabled BT analogue PSTN line A secondary communications path is provided using SMS signalling over the GSM network Even if an intruder cuts the line and jams the radio signals an alar...

Page 3: ...eds 42 4V peak AC or 60V DC If you have any doubt seek advice from a competent engineer before installing this or other adapters into the host equipment Static sensitive devices Static electricity is...

Page 4: ...ides an insulation displacement connection IDC block for the incoming phone line No connections other than those made by BT should be made to this IDC block The STU should be connected to the screw te...

Page 5: ...on TB1 For plug in installations be sure that no wires are ever connected to the terminals 1 to 8 on TB1 as this may result in damage to the alarm panel Terminals 9 10 11 T F can be connected if these...

Page 6: ...e such as a piezo bleeper or external strobe light should be connected through these contacts The maximum current rating of the relay contacts is 1 Amp STU specifications Pin alarm inputs Logic High 2...

Page 7: ...th the most common settings for most installations so generally the unit can be installed without the need to carry out configuration However if changes to the default setting are required they can be...

Page 8: ...pins have been configured the MODE button returns to the main menu iD hard ID number Pressing SET at the iD menu option enters the hard ID sub menu At factory default the unit has the last 4 digits o...

Page 9: ...ndline path has failed 1 Line Fault relay energised when landline path has failed 5G GSM STU 0 Line Fault relay de energised when both landline and GSM paths have failed 1 Line Fault relay energised w...

Page 10: ...and 20 minute forced poll on hook 2 Enable line monitoring PSTN earth calling mode 2 minute 20 sec forced poll on hook 3 Enable line monitoring PSTN voltage only Tip Type 1 will suit the majority of i...

Page 11: ...output for GSM 5G GSM STU only Pressing set at the F7 menu option allows the Function 7 value to be configured At factory default the F7 digit is set to 3 Note When F7 3 then pins 10 11 are used as pa...

Page 12: ...secs will trigger a 3 mins timeout before a pin 8 alarm is activated and LF relay operates If the Signal strength is 5 or more for greater than 50secs during the final 3 min timeout then the timeout w...

Page 13: ...alarm has been sent then restoring the pin F input will remain as showing AL F on the display until the 15min timeout has expired and the pin 13 restore has been sent and acknowledged re triggering F...

Page 14: ...ndition on input F to clear the pin 13 AC Fail alarm STU does not show AL 00 The STU will only display AL 00 when all inputs are in the restored state and all outstanding alarms have been acknowledged...

Page 15: ...Sale machine Credit card reader etc ESD Electro Static Discharge Form 175 BSIA document specifying dual path alarm signalling criteria GSM Global System for Mobile communications Groupe Sp cial Mobil...