80 / 150
Manual PRO50-150 V.2
When browsing through the menus, an arrow is displayed on the left hand side
→
which indicates the selected line.
When there is more than one line to select, the buttons
enable you to
move the arrow up or down to select the required option. The
OK
button
confirms selection.
When a value has to be adjusted, for example the time or level of chlorine, the
buttons
enable you to increase or decrease the value. Press the
OK
button to confirm the value.
4.1.2- Main screen
On starting up the equipment, a screen will be displayed with the main
parameters.
-
The upper line displays the production %, the voltage of the electrolysis
cell and the water temperature consecutively.(
If you do not have a
temperature probe, --- º will appear
).
-
The second line displays the oxidation /reduction potential called RedOx
or ORP (Oxidation Reduction Potential) or ppm if working with a free
chlorine probe. "Man.", "Auto" or "Semi-auto" is displayed on the right.
-
Important:
If you do not have a RedOx probe or a free chlorine probe,
the ORP reading displayed may be a random value. When selecting the
Manual mode (this mode is required if it is to operate without a probe),
the equipment will ask if you want to display the ORP line or to conceal
it.
-
The third line displays the pH reading as long as it is fitted in the
equipment (PRO model) and the relay status.
-
The fourth line displays the
→
Menu (press the
OK
button to access the
menu) and the time on the clock. If any alarm or warning occurs, it will
also be displayed on this line.