background image

BST Solutions GmbH  |  COMPACT FLAME DETECTOR IFR 400 

Page 7

GENERAL ASPECTS

Translations into foreign languages are carried out in good faith. We cannot accept any liabi-

lity for translation errors; this also applies where the translation has been carried out or has 

been commissioned by us. The original text alone shall be binding.

Descriptions and illustrations do not necessarily depict the delivered product or a possible 

spare parts order. Drawings and graphics are not to scale.

1.8  Declaration of conformity

1.9  Address of the manufacturer

BST Solutions GmbH

Ruegenstr. 7 . 42579 Heiligenhaus . Germany

T +49 2056 989 47-0 . E-Mail: info@flamonitec-bst.com
www.flamonitec-bst.com

 

 

 

 

 

 

 

BST Solutions GmbH 

Rügenstr. 7 

42579 Heiligenhaus 

Germany 

 

Tel.:   +49 2056 98947-0 

Web:  www.bst-solutions.de 

 

 

 

EU Konformitätserklärung 

EC Declaration of Conformity 

 

 

Produkt 

Flammenwächter IFCx, IFRx 

Product 

Flame detector IFCx, IFRx 

Typ 

IFC201, IFC400, IFR201, IFR400 

Type 

 IFC201, IFC400, IFR201, IFR400 

 

 

Hiermit erklären wir, dass der nachstehend bezeichnete Flammenwächter in seiner Konzipierung und 

Bauart sowie in der von uns in Verkehr gebrachten Ausführung den grundlegenden Sicherheitsanfor-

derungen folgender EU-Richtlinien entspricht 

 

This is to confirm that the below described system in its design and type of construction complies with the 

provisions of the Directive of the Council of the European Communities on the approximation of the laws of the 

member states relating to 

 

Verordnungen 

EU/2016/426 

 

Gasgeräteverordnung 

Regulations 

 

 

Gas appliances regulation 

 

2014/35/EU 

 

Niederspannungsrichtlinie 

 

 

 

Low voltage directive 

 

2014/30/EU 

 

EMV Richtlinie 

 

 

 

EMC directive 

Benannte

 

Stelle

 

Notified body 

DVGW Cert GmbH 

0085 

 

CE-Zertifikat vom 

CE certificate from 

Gültig bis 

Valid until 

03.04.2019 

 

03.04.2029 

 

CE-0085CU0083 

Baumusterprüfbescheinigung 

Type examination certificate 

 

Prüfgrundlagen 

EU/2016/426 A III B (09.03.2016) 

 

Standards 

EN 298:2012, EN13611:2015+AC:2016 

 

 

 

Ausgestellt durch            BST Solutions GmbH 

 

Issued by

 

 

 

 

Rechtsverbindliche  

Unterschrift 

Legally binding signature 

 

 

Name 

Funktion 

Ort, Datum 

 

 

Function

 

Place, Date

 

 

 

 

Eberhard Röllecke      Geschäftsführer 

Heiligenhaus, den 31.05.2021 

 

 

General Manager 

 

 

Summary of Contents for Flamonitec IFR 400

Page 1: ...Operating Manual Compact Flame Detector IFR 400...

Page 2: ...in case of maintenance and troubleshooting 2 5 1 Fundamental aspects 2 5 2 Electrical electronic devices 2 5 3 Testing per German Workplace Safety Ordinance BetrSichV 2 5 4 Safety test 3 Technical da...

Page 3: ...ion IFR 400 6 Operation of the compact flame detector IFR 400 6 1 Test of the compact flame detector 6 2 Operating indicator LED 7 Maintenance and servicing 7 1 Cleaning 8 Troubleshooting 9 Order data...

Page 4: ...g notes The following warning notes are used in these operating instructions This warning level indicates an imminent hazardous situation If the hazardous situation is not prevented this will result i...

Page 5: ...erating malfunctions that result from the operating manual not being observed The operating company has to supplement the operating manual with operating instructions on the basis of national regulati...

Page 6: ...t of our knowledge correct at the time of printing taking into account our present understanding and experience We reserve the right to make technical changes with respect to the further development o...

Page 7: ...n wir dass der nachstehend bezeichnete Flammenw chter in seiner Konzipierung und Bauart sowie in der von uns in Verkehr gebrachten Ausf hrung den grundlegenden Sicherheitsanfor derungen folgender EU R...

Page 8: ...rugs alcohol or medication that affects reactivity shall not be permitted to carry out work on the device Connection set up maintenance and repair work may only be carried out by qualified spe cialist...

Page 9: ...ceable damage and defects prior to using the device Immedia tely notify the appropriate authority person of any changes that occur including changes in operating performance If necessary stop and secu...

Page 10: ...replacement of parts assemblies have to be ob served These tasks may only be carried out by authorised specialist staff Operating staff have to be informed before maintenance or other special work is...

Page 11: ...e opening the housing the device must be deenergized 2 5 3 Testing per German Workplace Safety Ordinance BetrSichV In case of the coupling or installation of devices from various manufacturers or supp...

Page 12: ...n time Switch on time Switch off time 1s 1s With the sensitive variant the switch off time changes to For installations in accordance with DIN EN 267 or DIN EN 676 at the moment of self checking 2s Th...

Page 13: ...rox approx 0 750 kg 3 4 Dimensions Length without plug or gland 192 1 mm Width 66 mm Height 92 mm Dimensions see under item 4 4 3 5 Block diagram IFR 400 Item Designation 1 Sensor 2 Shutter 3 Preampli...

Page 14: ...ase to the insurance company without delay and transmit the full claim documents at once in order to expedite the claims settlement at the latest in suf ficient time before the expiry of any periods o...

Page 15: ...is to be avoided The connecting cable is to run separately from the high energy ignition and power lines over long distances and not parallel to avoid interference All installation and connection work...

Page 16: ...acked compact flame detector IFR 400 and accessories The following conditions apply to storage Store in a dry place Maximum relative humidity 95 Non condensing In addition ensure that the floor in the...

Page 17: ...tector To ensure the proper operation the compact flame detector must be tested several times by starting and stopping the burner As long as there is no flame in all cases the flame relays has to be s...

Page 18: ...shooting Do not scratch the glass NOTICE Error description Cause Remedy No flame signal connecting error or no active power Glass dirty IFR 400 malfunction Please check the plugs an the connections of...

Page 19: ...nection cable 1 5m 230 V AC 611199010462 Compact Flame Detector IFR 400 120 sensitive fixed connection cable 1 5 m 120 V AC 611299010452 Compact Flame Detector IFR 400 120 sensitive Ionization fixed c...

Page 20: ...BST Solutions GmbH Ruegenstr 7 42579 Heiligenhaus Germany T 49 2056 989 47 0 info amonitec bst com www amonitec bst com Subject to technical changes BST Solutions 2021 MEMBER OF MINDERMANN GROUP...

Reviews: