background image

UPB-120 USB / UPB-240 USB              

 

 

© Copyright LOTRONIC 2012                                      

 

Page 9 

 

10. ZONE LED 

These led light’on when you select the corresponding zone 

11. ZONE SELECT 

The power amplifier have 5 zones outputs. You can seperate speaker by zone. With these button, you can choose in which zone you want 
to send the sound. The ALL ZONE nutton is used to select all in same time  

12. VUMETER 

These LED display shows the level of what ever is present on general output. If the led 2 to 10 light, the operating and level are OK. If the 
led 12 lights, that means the level is too high and the output is in distortion. So you must to decrease level of all input levels. 

13. PROTECTION LED 

This led light’s on when something is wrong on the power amplifier ( inside or outside like the speakers ). If this led ligh’s on, unplugged the 
speakers. If led stay on, that means your power amplifier have a electronic problem. In this case, please contact your dealer or the BST 
PRO technical service. 

14. HEAT LED 

If this led light’s on, that means you power amplifier is in overheat. Stop it and check if fan is not blocked or obstructed 

15. USB LEVEL CONTROL 

Use this button to adjust the level of USB input 

16. LOOP BUTTON 

This button is used to make a loop either one file, either all the files 

17. NEXT BUTTON 

       This button is used to select the next MP3 file) 

18.  PLAY / PAUSE BUTTON 

Each press of the button to change from play to pause or from pause to play 

19. PREV BUTTON 

This button is used to select the previous MP3 file 

20. DISPLAY  

The display shows : playback state ( play, pause, stop ), time, the current play track mp3 file and the total of files 

21.  POWER SUPPLY FUSE 

Plug the AC power cord on this socket. Before plugging this cord in, be sure the voltage of AC outlet is correct. ( 220V ) 
The fuse is used to protect your power amplifier from different kinds of ac problems. If  the power amplifier  is “on” and nothing lights, please 
verify the fuse compartment. If fuse is broken, please read it and change with a new one of same size and value. 

22. SPEAKER OUTPUT 

These output are used to connect low impedance speaker, 70V speaker or 100V speaker 

23.  EMC INPUT ( EMERGENCY ) 

Connect on these inputs emergency periphericals ( emergency message, emergency ringing,... ). This input have a priority function. It 
decrease the volume of all inputs ( except mic 1 input ). 

24. MUTE CONTROL 

This control is used to adjust the level of decrease for priority function. This function operates on all input ( except mic 1 ). 
On the min control, the function is disable. 
Inputs recover their normal level if the user stops to talk on the mic 1 input more than 3s. 

25.  MIC 2 & 3 INPUTS ( MIC LEVEL ) 

Connect on these inputs the receiver of a wireless microphone ( MIC level ). The XLR socket have fantom power suplly. 
Connector : Jack 6.35mm + XLR 

26.  MIC 2 & 3 INPUTS (LINE LEVEL ) 

Connect on these inputs the receiver of a wireless microphone ( line level ). As the level of this input is line, you can connect on this input 
only items with line level ( cd player, tape player, minidisc, mixer,... ). You cannot connect turntable ( phono level ) or microphone ( mic 
level ) 

27.  AUX 1 & 2 INPUTS  

The level of these inputs are line so you can connect on these inputs only items with line level ( cd player, tape player, minidisc, mixer,... ). 
You cannot connect turntable ( phono level ) or microphone ( mic level ) 

28. LINE OUT 

The signal of this output is the same of the main signal so you you can use this output to connect a secondary power amplifier.) 

29. FAN 

This fan is used to aircolled the power amplifier. Please dont blocked this fan. 

30.  MIC 2 AND 3 PHANTOM POWER BUTTON 

Phantom power, in the context of professional audio equipment, is a method for transmitting DC electric power through microphone cables 
to operate microphones that contain active electronic circuitry.It is best known as a convenient power source for condenser microphones, 
though many active direct boxes also use it. If the mic connected on the mic 2 and 3 inputs are a condenser microphone, please push these 
buttons to activate phantom power 
Note: If the microphone connected on the mic input is a dynamic mic, disable phantom power or you will destruct the mic 

31.  MIC 2 AND 3 GAIN CONTROL ( XLR ) 

These rotary potentiometers is used to adjust the gain of mic 2 and 3 XLR inputs 
Note : don’t adjust the gain to high or the sound must be saturated 

32.  SPEAKERS ZONE OUTPUT 

Connect 100V speakers on each zone. 

Summary of Contents for UPB-120 USB

Page 1: ...UR R M MI IX XE EU UR R L LI IG GN NE E 1 10 00 0V V L LI IN NE E 1 10 00 0V V P PO OW WE ER R A AM MP PL LI IF FI IE ER R M MI IX XE ER R UPB 120 USB UPB 240 USB GB INSTRUCTION MANUAL F MANUEL D UTILISATION D BEDIENUNGSANLEITUNG NL HANDLEIDING PT MANUAL DE INSTRUÇÕES RO MANUAL DE UTILIZARE ...

Page 2: ... dispositif de déconnexion l emplacement sur l appareil et la fonction de l interrupteur doit être décrite et le commutateur doit rester facilement accessible ATTENTION 1 Les dommages résultant du non respect des instructions ou de la modification de l appareil ne sont pas couverts par la garantie Tenir loin des enfants et des personnes non qualifiées 2 L appareil ne contient aucune pièce remplaça...

Page 3: ...ées auxilliaire 1 et 2 Attention Le niveau d entrée est du type line c est à dire que vous pouvez brancher soit un lecteur CD un lecteur minidisc une table de mixage un lecteur K7 Vous ne devez pas connectez un micro niveau micro ou une platine vinyle niveau phono 5 RÉGLAGE TONALITÉ BASSE Ce potentiomètre ajuste les fréquences basses bass du signal général 6 RÉGLAGE TONALITÉ HAUTE Ce potentiomètre...

Page 4: ...ion 220V 50Hz Le fusible permet de protéger l amplificateur contre tout problème électrique En cas de destruction du fusible veuillez le remplacer par un de même taille et de même valeur 22 BORNIER SORTIE HP Ce bornier va vous permettre de brancher un ou plusieurs haut parleurs impédance 4 à 16 ohms ou sortie 100V et 70V 23 ENTRÉES EMC URGENCE Connectez un périphérique d urgence message d alerte s...

Page 5: ...enceintes Sur la sortie 70V vous pouvez connecter un ou plusieurs haut parleurs PA 70V équipé de transfo Attention Le nombre de haut parleurs en sortie dépend de la puissance de l ampli et de la puissance des haut parleurs exemple si votre ampli fait 60W comme l UPA 60 et que la puissance d un HP est de 15W vous ne pourrez mettre que 4 HP en sortie 4x15W 60W Connectez la sortie 70V de l ampli sur ...

Page 6: ... GARANTIE Les équipements BST PRO sont couverts par une garantie de 2 ans pièces et main d œuvre Les principes suivants s appliquent à partir du moment où l appareil quitte nos usines La facture de mise à la consommation sera foi de date de départ de la garantie dans la mesure ou celle ci n excède pas 12 mois par rapport à la date de fabrication Seules les compagnies agréées par BST PRO sont autor...

Page 7: ...pliance coupler is used as the disconnect device the disconnect device shall remain readily operable CAUTION 1 Please be aware that damages caused by manual modifications to the device are not subject to warranty Keep away from children and non professionals 2 The light doesn t include any spare parts for repair please check if all the parts are well installed and screws are fitted tightly before ...

Page 8: ...lks on the microphone plugged on the mic 1 input the level of the rest of inputs MIC 2 3 AUX 1 and AUX 2 automatically decrease the level of decrease depends to mute level setup When the user stop to talk on the mic 1 more than 3 seconds the level of inputs recover their normal level 4 AUX 1 2 LEVEL CONTROLS These controsl are used to adjust the level of the AUX inputs Attention The level of this ...

Page 9: ...r 70V speaker or 100V speaker 23 EMC INPUT EMERGENCY Connect on these inputs emergency periphericals emergency message emergency ringing This input have a priority function It decrease the volume of all inputs except mic 1 input 24 MUTE CONTROL This control is used to adjust the level of decrease for priority function This function operates on all input except mic 1 On the min control the function...

Page 10: ...ier socket of the PA speaker Connect the com socket of the power amplifier on the socket of the PA speaker Note In P A for more operating security you must to keep 20 of free power On each zone outputs you can connect one or severals PA speaker Note The total power of the PA speakers is equal to power of the power amplifier For example if you have a 120W power amplifier and 15W PA speaker you must...

Page 11: ... allowed to work on the equipment Warranty becomes void when other service technicians open the equipment During warranty period defective equipment must be sent by pre paid mail in the original box BST PRO will return the goods by pre paid mail during the first year of warranty thereafter the mailing cost is to be paid by the recipient Potentiometers have a limited lifetime and are not covered by...

Reviews: