Motor-driven blocking device EasyBlocker
Installation
instruction
108320
2.2.3 Actuating with a static signal
This may be the activated and not activated exit of an BURGLAR ALARM CENTER or it may be a timely
limited release signal for access control applications.
A) Static signal at the open entry
When activating the
Open
entry the blocking device opens, when deactivating the blocking device closes.
The
Closed
entry
always
needs to be switched active.
Signal progress and switch on example with "0V activated"-"inactivated" signal:
Illustration 2-7
8320AB207en.tif
Illustration 2-8
8320AB208en.tif
When controlling the
Open
entry via a PNP transistor upon +12V the
mutual
needs to be put on
0 V
and
the
Closed
entry on
+12 V
.
B) Static signal at the closed entry
When activating the
Closed
entry the blocking device closes, when deactivating the blocking device
opens. The
Opened
entry
always
needs to be switched active.
Signal progress and switch on example with
„0V-activated“
-
„activated“
signal:
Illustration 2-9
8320AB209en.tif
Illustration 2-10
8320AB210en.tif
When controlling the
Closed
entry via a PNP transistor upon +12V the
mutual
needs to be put on
0 V
and
the
Opened
entry on
+12 V
.
108320Err_ENG.doc
version 6.0a / 06.04.2016
page 9