Motor-driven blocking device EasyBlocker
Installation instruction
108320
2.2.1 General information
The device can be switched on in 6 different ways. In doing so, the actuation is enabled with a static
signal or 2 dynamic signals. The polarity of the input signals is arbitrary due to an mutual connection.
Furthermore, there are 2 outputs available which signalize the status of the blocking device. This way, the
blocking device can be easily adapted to any system.
There are measures provided for electrical emergency opening such as the option to interrupt the supply
voltage. Please find further information regarding the electrical emergency opening in
2.2.2 Actuation with dynamic signals
These are timely limited impulses for the open and close actuations which are also used to actuate
bistable door openers. For the impulse length the following values need to be observed:
Impulse length:
> 50 ms
for the standard versions
> 200 ms
for the battery versions
The impulse is saved in the blocking device and the closing or opening process is performed.
Signal progress:
Illustration 2-4
8320AB204en.tif
Impulse term:
≥
50 ms
(Standard version)
≥
200 ms (Battery version)
Examples for switching on:
With outputs switching upon
0 V
„Door
opened“
and
„Door closed“
(
0V activated
)
With outputs switching upon
+12 V
„Door
opened“
and
„Door closed“
(
+12V activated
)
Illustration 2-5
8320AB205en.tif
Illustration 2-6
8320AB206en.tif
page 8
version 6.0a / 06.04.2016
108320Err_ENG.doc