background image

IMPORTANT SAFETY INSTRUCTIONS

ELECTROMAGNETIC COMPATIBILITY 

This device complies with part 15 of the FCC Rules and the Product 

Specifications noted on the 

Declaration of Conformity

. Operation 

is subject to the following two conditions:
•   this device may not cause harmful interference, and 

•   this device must accept any interference received, including 

interference that may cause undesired operation.  

Operation of this unit within significant electromagnetic fields should be 

avoided.
•  use only shielded interconnecting cables.

DECLARATION OF CONFORMITY

Manufacturer’s Name:  BSS Audio
Manufacturer’s Address:  10653 S. River Front    
 

Parkway, Suite 300

 

South Jordan, Utah    

 

84095, USA 

declares that the product:

Product name:  BLU 120, BLU 160,    
 

BLU 320, BLU 325,    

 

BLU 326, BLU 800,    

 

BLU 805 and BLU 806

Note: Product name may be suffixed by a 
combination of the letters EU, M, or V.

Product option:  Various I/O Cards

conforms to the following Product Specifications:

Safety: 

IEC 60065 -01+Amd 1 & 2

EMC: 

EN 55022:2010 

 

EN 55024:2010

 

FCC Part 15

Supplementary Information:

The product herewith complies with the 
requirements of the:
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
WEEE Directive 2012/19/EU

With regard to Directive 2005/32/EC and 
EC Regulation 1275/2008 of 17 December 
2008, this product is designed, produced, and 
classified as Professional Audio Equipment and 
thus is exempt from this Directive.

C. Rex Reed
Director, Engineering
Signal Processing
10653 S. River Front Parkway, Suite 300
South Jordan, Utah 84095, USA 
Date: August 15, 2016

European Contact:

Harman International
Salisbury House
London Wall
EC2M 5QQ
+44 207 562 9450

or

Harman Professional Inc.
10653 S. River Front Parkway, Suite 300
South Jordan, Utah 84095, USA 
Ph: (801) 566-8800
Fax: (801) 568-7583

DECLARATION OF CONFORMITY

Manufacturer’s Name:  BSS Audio
Manufacturer’s Address:  10653 S. River Front    
 

Parkway, Suite 300

 

South Jordan, Utah    

 

84095, USA 

declares that the product:

Product name:  BLU 326 (DA) and 806 (DA)
Note: Product name may be suffixed by a 
combination of the letters EU, M, or V.

Product option:  Various I/O Cards

conforms to the following Product Specifications:

Safety: 

IEC 60065: 8th Ed. 2014

EMC: 

EN 55032: 2012

 

EN 55024: 2010

 

FCC Part 15

Supplementary Information:

The product herewith complies with the 
requirements of the:
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
WEEE Directive 2012/19/EU

With regard to Directive 2005/32/EC and 
EC Regulation 1275/2008 of 17 December 
2008, this product is designed, produced, and 
classified as Professional Audio Equipment and 
thus is exempt from this Directive.

C. Rex Reed
Director, Engineering
Signal Processing
10653 S. River Front Parkway, Suite 300
South Jordan, Utah 84095, USA 
Date: March 14, 2017

European Contact:

Harman International
Salisbury House
London Wall
EC2M 5QQ
+44 207 562 9450

or

Harman Professional Inc.
10653 S. River Front Parkway, Suite 300
South Jordan, Utah 84095, USA 
Ph: (801) 566-8800
Fax: (801) 568-7583

SAFETY INSTRUCTIONS

NOTICE FOR CUSTOMERS IF YOUR UNIT IS EQUIPPED WITH A POWER CORD.

WARNING: THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE 
EARTHING CONNECTION.

THE CORES IN THE MAINS LEAD ARE COLOURED IN ACCORDANCE WITH THE FOLLOWING CODE:

GREEN AND YELLOW - EARTH        BLUE - NEUTRAL        BROWN - LIVE

AS COLOURS OF THE CORES IN THE MAINS LEAD OF THIS APPLIANCE MAY NOT CORRESPOND WITH THE 
COLOURED MARKINGS IDENTIFYING THE TERMINALS IN YOUR PLUG, PROCEED AS FOLLOWS:

•    THE CORE WHICH IS COLOURED GREEN AND YELLOW MUST BE CONNECTED TO THE TERMINAL IN 

THE PLUG MARKED WITH THE LETTER E, OR WITH THE EARTH SYMBOL, OR COLOURED GREEN, OR 
GREEN AND YELLOW.

•    THE CORE WHICH IS COLOURED BLUE MUST BE CONNECTED TO THE TERMINAL MARKED N OR 

COLOURED BLACK.

•  THE CORE WHICH IS COLOURED BROWN MUST BE CONNECTED TO THE TERMINAL MARKED L OR 

COLOURED RED.

 
THIS EQUIPMENT MAY REQUIRE THE USE OF A DIFFERENT LINE CORD, ATTACHMENT PLUG, OR BOTH, 
DEPENDING ON THE AVAILABLE POWER SOURCE AT INSTALLATION.  IF THE ATTACHMENT PLUG NEEDS TO 
BE CHANGED, REFER SERVICING TO QUALIFIED SERVICE PERSONNEL WHO SHOULD REFER TO THE TABLE 
BELOW. THE GREEN/YELLOW WIRE SHALL BE CONNECTED DIRECTLY TO THE UNITS CHASSIS.

CONDUCTOR

WIRE COLOR

Normal

Alt

L

LIVE

BROWN

BLACK

N

NEUTRAL

BLUE

WHITE

E

EARTH GND

GREEN/YEL

GREEN

WARNING:

 IF THE GROUND IS DEFEATED, CERTAIN FAULT CONDITIONS IN THE UNIT OR IN THE SYS-

TEM TO WHICH IT IS CONNECTED CAN RESULT IN FULL LINE VOLTAGE BETWEEN CHASSIS AND EARTH 
GROUND. SEVERE INJURY OR DEATH CAN THEN RESULT IF THE CHASSIS AND EARTH GROUND ARE 
TOUCHED SIMULTANEOUSLY.

WARNING: 

•  APPARATET MÅ TILKOPLES JORDET STIKKONTAKT. 
•  APPARATEN SKALL ANSLUTAS TILL JORDAT UTTAG. 
•  LAITE ON LIITETTÄVÄ SUOJAKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN. 
•  APPARATET SKAL TILSLUTTES JORDET STIKKONTAKT.

Summary of Contents for BSS Soundweb London BLU-326

Page 1: ...Soundweb TM London BLU 800 BLU 805 BLU 806 BLU 806DA BLU 320 BLU 325 BLU 326 BLU 326DA BLU 160 BLU 120 Installation Guide 5086087 A...

Page 2: ...ude use do not use this product above 2000m WARNING FOR YOUR PROTECTION READ THE FOLLOWING READ THESE INSTRUCTIONS KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS DO NOT USE THIS APP...

Page 3: ...s with the requirements of the Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU RoHS Directive 2011 65 EU WEEE Directive 2012 19 EU With regard to Directive 2005 32 EC and EC Regulation 1275...

Page 4: ...RE S CURIT LIRE ATTENTIVEMENT LIRE CES CONSIGNES CONSERVER CES CONSIGNES RESPECTER TOUS LES AVERTISSEMENTS SUIVRE TOUTES LES CONSIGNES NE PAS UTILISER CET APPAREIL PR S DE L EAU NETTOYER UNIQUEMENT AV...

Page 5: ...ITETT V SUOJAKOSKETTIMILLA VARUSTETTUUN PISTORASIAAN APPARATET SKAL TILSLUTTES JORDET STIKKONTAKT D CLARATION DE CONFORMIT Nom du fabricant BSS Audio Adresse du fabricant 10653 S River Front Parkway S...

Page 6: ...TE 2 Contrast Hold 2 Rear Panel 3 AC Mains 3 CobraNetTM Connectors Primary Secondary BLU 800 BLU 320 3 AVB BLU 805 BLU 325 3 DanteTM AES67 BLU 806 DA BLU 326 DA 3 BLU link 3 Locate 4 RS232 4 Ethernet...

Page 7: ...USA BY BSS AUDIO RS232 LOCATE S S S S S S S S S S S S S S S S WORDCLOCK T1 6AH 250V FUSE 100 240V 50 60Hz 55W CobraNet BLUlink IN OUT If the unit is likely to undergo extreme vibration through extens...

Page 8: ...ith a Master LED on the front panel of the device that is providing the master clock function Network Link The Network Link indicates the presence of Cat 5 Ethernet cables If no cables are connected t...

Page 9: ...nabled It will be enabled in a future release of HiQnet London Architect The physical AVB connections must be made using Cat 5e cables and an AVB compatible network switch See Technical Specifications...

Page 10: ...on If Box B ceases to receive the 48kHz system clock from Box A due to power failure of Box A Box B will take over and begin receiving and transmitting audio over the CobraNetTM network These connecto...

Page 11: ...12 control inputs and two software assignable reference voltage outputs R to the right The control ports have two modes of operation 2 wire and 3 wire 2 Wire Mode In this mode the 12 control inputs a...

Page 12: ...LED relay When sourcing from the Logic Output an LED connected between one output Anode A and common Cathode K will illuminate when the logic output is activated without requiring any external current...

Page 13: ...electronically balanced on Phoenix Combicon removable screw connectors MIC LINE INPUTS Nominal gain 0dB electronically switchable up to 48dB in 6dB steps INPUT IMPEDANCE 3 5kOhm MAXIMUM INPUT LEVEL 2...

Page 14: ...ctor for failsafe control OPTO OUTPUT CURRENT 14mA maximum WITHSTANDING VOLTAGE 80V maximum Off SERIES IMPEDANCE 220 Ohms isolated CONTROL NETWORK CONNECTORS RJ45 Ethernet connector MAXIMUM CABLE LENG...

Page 15: ...ical fans have a limited life expectancy We recommend annual inspection of fans for dust occlusion and excessive noise Fan assemblies should be replaced after six to ten years of use Environmental fac...

Page 16: ...Phone 801 566 8800 Website bssaudio com Support bssaudio com en US support BSS Audio is a registered trademark of HARMAN 2017 HARMAN All rights reserved Printed in Malaysia...

Reviews: