AR 130 PHASE CHECK SYSTEM 

 
 

IMPORTANT  - 

On receipt of these units, check for visible damage.  Any claims for transit 

damage must be made within 14 days of receipt to be covered by warranty.  It is important 

that  all  repairs  are  carried  out  by  an  authorised  BSS  agent,  as  evidence  of  internal 

tampering may invalidate this warranty. 

 

TO  OBTAIN  THE  BEST  POSSIBLE  RESULTS,  THIS  MANUAL  MUST  BE  READ  PRIOR 
TO USE. 
 
INTRODUCTION 
 

The  AR130  test  system  is  a  specialist  piece  of  equipment  for  checking  the  phase 

correctness  between  input  and  output  of  most  electrical,  electronic  or  electro-mechanical 

units.  This unit must have at least one two-wire port, which need not be balanced.  Such 

examples  are  multiway  connecting  cables,  equipment  racks,  sound  mixing  consoles, 

microphones and loudspeakers. 

 

The  test  system  consists  of  a  SOURCE,  the  AR13OS,  and  a  DETECTOR,  the  AR130D.  

The  source  provides  an  encoded  test  tone,  and  is  normally  connected  to  the  equipment 

input.  The detector dictates the phase, either in or out, between input and output, and is 

connected  to  the  output  of  this  equipment.    For  units  which  are  frequency  dependant, 

provision is made to adjust the test tone frequency.  Also available is a foam lined carrying 

case to house the phase check set, two XLR balanced to unbalanced converters and two 

spare batteries. 

 

1.0 

GENERAL 

 
1.1 

Batteries 

 

Ensure unit is switched off before fitting two 9 volt, PP3 sized batteries, and check carefully 

for  correct  orientation.    It  is  strongly  recommended  that  alkaline  type  cells  are  used,  as 

these will give extended life, and also provide enough power for the AR130S to drive an 8 

ohm loudspeaker directly.  On switching on the source, the range LED will illuminate, and 

the step switch will allow selection of the frequency range.  For the detector, only the ON 

LED  will  illuminate.    If  the  battery  low  LED  illuminates  check  both  batteries  and  their 

connections. 

 

1.2 

Checking Operation 

 

It  is  possible  to  check  the  correct  operation  of  the  system  by  connecting  the  source  and 

detector directly together with a standard balanced lead.  The detector's green phase LED 

will illuminate when the source output switch in the N position, and the red one when this 

switch in the R position.   This action can also be checked on all four frequency ranges, and 

a range of source output level. 

 

1.3 

Connection 

 

AR130:    Before  connection  to  your  equipment,  check  the  connector  wiring  diagram  for 

compatibility.  If used on an unbalanced system, the supplied XLR converter can be used to 

provide  the  necessary  rewiring.    AR130D:  this  has  a  universal  input  wiring  configuration, 

enabling all forms of wiring to be accommodated for without the need to use converters. 

 

 