BOB’S SPACE RACERS®
3 IN 1
3 In 1 Event Trailer Operations Manual
14
Oil Free Air Compressor
Drain Valve
(Condensation)
The Drain Valve is located at the base of the air tank
and is used to drain condensation at the end of each
use / day.
Quick Troubleshooting
TROUBLESHOOTING PHILOSOPHY
When troubleshooting any product, certain general guidelines should be followed.
1. Always check to be sure that you game is turned on. Be sure that all of the fuses in the game are functional and
check to see that the AC voltage is in the proper operating range for your game.
2. Check to be sure that all of the game harnessing is plugged in properly and that all of the pins are firmly seated in
the connectors. It is always possible that a harness can be damaged by rough shipping or moving.
3. Check game harnessing to be sure that none of the wires have become damaged. Using a handheld multi-meter,
check continuity of the wires to make sure they are not broken.
4. Check for obvious damage to any P.C. Boards or electrical components.
5. If you have multiple games or multiple parts on a game, change or exchange the parts and see if the problem goes
away or moves to another location. This way you can quickly eliminate certain parts as being the problem with the
game.
6. When changing electronic or electrical components, ALWAYS turn off and unplug the game.
7. Check to see that all power supplies are delivering the specified voltages to the P.C. Boards and components as
shown in the manual.
For detailed servicing and repair information see the full the full repair section of this manual.
For your safety and to reduce risk of damage to your game read the Important Safety
Information on page 5 before attempting any troubleshooting procedure.
WARNING
Drain Valve