![BSi MT6900 Series Installation Instructions Manual Download Page 5](http://html1.mh-extra.com/html/bsi/mt6900-series/mt6900-series_installation-instructions-manual_2823440005.webp)
Indoor
B.
Strike i
nstallation
1.
Drill a Ø 28.4mm hole with 25mm depth and 135 High on the center of strike outline.
2.
Use the chisel to scrape out the door frame for 160.4mm high, 28mm width and
1.5mm deep.
3.
Drill Ф3.0mm with 15mm Depth of screw holes (top and bottom).
4.
Then insert the strike plate and tighten it with screws. Be sure the holes for thru-bolts
should be horizontally aligned. Ensure to chisel deep enough to allow the strike lay
flush with the frame surface.
Attention
:
When the door edge size is more than 65mm, please use the specific thrust
plate.
Schematic diagram for install thrust
plate (When door edge is less than
65mm)
Schematic diagram for install thrust
plate (When door edge is more than
65mm)
C.
Install lock case & cylinder
1.
Make sure the lock hand to match door hand, use the following diagram to
determine the hand of door.
4
Door Opening
Direction
Door
Hinge
Left Hand Open
(LH)
Outdoor
Right hand open
(RH)