Bryston 7b3 Owner'S Manual Download Page 9

7B

3

 Amplifier

9

6. Output Binding Posts:

The RED binding post is connected to the 

amplifier output. Connect to this post the (+) 

terminal on the loudspeaker.. 

The BLUE binding post is connected to the 

negative (-) output. Connect to this post the (-) 

terminal on the loudspeaker.

Never connect either binding post to an 

electrical ground!

The output binding posts provide three different 

interconnect options: banana plugs, spade lugs, 

and bare wire. Combinations may be used when 

bi-wiring.  Cables should be kept as short as 

practical and should never be terminated with 

connectors that may become confused for AC 

power connectors. Cables should be dressed 

away from input and power cables.

Only use Class 2 Rated Wiring. No other wiring is 

permitted for use.

7. Master Circuit Breaker: 

The Cubed series amplifier uses a magnetic-

trip circuit breaker to protect the amplifier. 

This breaker is not an on off switch and must 

be in the ‘ON’ position during the installation 

and normal operation. Use the front panel 

push-button power switch or an external 

control voltage to power-up or power-down 

the amplifier. Should the breaker trip, or switch 

“OFF”,  lower or remove the amplifier input 

signals. Remove the AC power by disconnecting 

the power cord from the amplifier for 20 

seconds. Switch the breaker to the ‘ON’ position. 

Reconnect the power cord, then power the unit 

up normally. The circuit breaker must be ‘ON’ 

at all times for the Cubed Series amplifier to 

operate.

8. A/C Power Input: 

An IEC-320 C14 power inlet provides for 

connection of an IEC-320 C13 equipped power 

cord.  Before connecting the power cord to the 

amplifier, check that the voltage rating on the 

data plate or ratings label conforms with your 

locality. With the circuit breaker ‘ON’ insert the 

power cord into the Cubed series amplifier, then 

plug the other end to an appropriate A/C outlet.

9. Remote Power Up:

When in External position, the Power On state 

is governed by voltage applied to IN terminals 

of the Remote Power Up connector. The front 

panel power switch must remain in the ‘ON’ 

position. “External Control Voltage” on page 

6 for instructions regarding connection and 

usage.

10.  Power Status Indicator:

Plugging in the power cord applies power to 

the amplifier. The status indicator will initially 

flash green. The number of flashes indicates the 

revision of the soft start circuit software. This 

puts the amplifier in Standby mode and the LED 

turns red indicating power is present.

Engaging  the front panel on/off switch initializes 

the startup sequence. During the soft start ramp 

up, operation the status led will turn orange 

when connected to 60Hz power or red when 

connected to 50Hz power. The Status LED 

switches to green when the ramp up sequence 

ends. Turning off the front panel on/off switch 

returns the amplifier to the Standby mode.

11.  Data Plate:

Unit specific information is printed here 

including model number, operating voltage, 

frequency and serial number. 

7B3-17-SIL-120

~120V   60Hz   1100W

Serial No:      7B3-000000

Date: 1530    REV: 1234 

Summary of Contents for 7b3

Page 1: ...7B3 Amplifier Owner s Manual ...

Page 2: ...E BRYSTON LIMITED WARRANTY Bryston analog audio products are warranted to be free from manufacturing defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts exclu...

Page 3: ...Description 4 Features 4 Shipping Box and Packing Material 4 Installation and Usage 4 Ventilation 4 Connecting to A C Power 4 Connecting to Loudspeakers 5 Balanced vs Single Ended Input 5 Power Conditioners 6 Front Panel 7 Rear Panel 8 7B3 Specifications 10 Dimensions 11 ...

Page 4: ...riginal packing material as the unit is not insurable by carriers otherwise Replacement packing materials consisting of a shipping carton with plastic foam inserts is available from Bryston for a small fee Installation and Usage Ventilation Bryston has deliberately chosen to omit fans from our amplifiers in an effort to minimize the noise level in your listening environment Instead we use only pas...

Page 5: ...ole in the binding post and held in place by tightening the post knob Additional tightening pressure can be achieved using a coin in the slots of the knob Do not over tighten or the binding post may become damaged Note that copper wire is malleable and may require further tightening after the initial installation To prevent the risk of equipment damage or personal harm use only Class 2 rated louds...

Page 6: ...ision and clarity External Control Voltage To power up the amplifier using an external control voltage supply a 5V to 12V AC or DC control voltage to the IN terminals of connector fig 1 Use paired wire of 22 to 18 gauge between the source device and the Bryston Cubed series amplifier The appropriate mating connector is supplied with each amplifier Set the External Turn On switch to External See 9 ...

Page 7: ...the amplifier output level no longer can follow the level increase at the input over driven input condition When a channel is driven into clipping the channel LED will change from green to red then back to green when the level is reduced Momentary clipping can be tolerated however it indicates that maximum undistorted power has been surpassed and potential speaker damage may result if overload con...

Page 8: ...ion Or use this setting whenver less gain is required The 23dB setting equates to an output of 100w 8 ohms for 2V input noise 116 dB The noise is referenced in dB below rated output Different input configurations result in slightly different noise readings The above noise ratings represent minimum readings Actual readings may be better 5 Channel Level Attenuator PRO ONLY The level control will att...

Page 9: ...l times for the Cubed Series amplifier to operate 8 A C Power Input An IEC 320 C14 power inlet provides for connection of an IEC 320 C13 equipped power cord Before connecting the power cord to the amplifier check that the voltage rating on the data plate or ratings label conforms with your locality With the circuit breaker ON insert the power cord into the Cubed series amplifier then plug the othe...

Page 10: ...dividual Mode Single Ended Balanced Balanced 10kΩ 10kΩ 10kΩ IMD 0 005 Typ 0 002 THD N 20Hz 20kHz 600W 8Ω 0 005 Noise SE input shorted 20Hz 20kHz High 29dB Low 23dB 113dB 78dBu 116dB 81dBu Slew Rate 60V µS Bandwidth 1Hz to 100kHz Damping 20Hz 8Ω 300 Weight Pounds Kilograms 42 19 1 Power Consumption Watts Standby Idle 600W 8Ω 75W 8Ω 0 5W 80 1100 725 Heat Load BTU Hour Idle 600W 8Ω 75W 8Ω 270 3750 25...

Page 11: ...7B3 Amplifier 11 Dimensions Minimum recommended clearance for heat dissipation ...

Page 12: ...Bryston Limited 677 Neal Drive Peterborough Ontario K9J 6X7 Canada Phone 705 742 5325 www bryston com 300044 2016 01 19 ...

Reviews: