Bryston 6BSST2 Owner'S Manual Download Page 7

 

AC POWER INPUT

 

 This is a high current plug for the power cord receptacle. Check that the 

voltage rating at the right of the connector conforms with your locality. 

With the circuit breaker ‘OFF’ insert the power cord into the 

6B

SST

2

, then 

plug the other end to an approprate A/C power outlet. 

 

 LOCAL / EXTERNAL SWITCH

 

 To power-up the 6B

SST

2

 using an EXTERNAL control voltage, place the 

LOCAL/EXTERNAL switch in the EXTERNAL position and supply a 4v to 

12v  A/C or DC control voltage to the ‘IN’ terminals of 

External Turn-On 

Connector

 (item #4). 

      When the control voltage is removed or drops below 3 Volts the amplifier 

will turn off.  Immediately following power 

up the control voltage will appear at the 

’OUT’ terminals of the 

External Turn-On 

Connector

 for the control of other equip-

ment. It is removed whenever the ampli-

fier is turned off.

  

 In the 

LOCAL

 mode (with the LOCAL/

EXTERNAL switch set to LOCAL) the 

6B

SST

2

 will ignore the control voltage, 

and power up only by using the front panel  ‘

6B

SST

2

’ switch, or as in section 3 above. If a control voltage is present 

at the ‘IN’ terminals it    will still be available at the ‘OUT’ terminals after the power-up sequence.

  Note:

 

 The ‘OUT’ terminals are connected to the ‘IN’ terminals once the 

6B

SST

2

 has powered-up. The control current is 

determined by the 

source 

equipment. The carrying current of the ‘OUT’ relay is 2 amps. The 

6B

SST

2

 itself draws 

less than 2 ma from the control current when operating.

 REMOTE POWER TURN-ON CONNECTOR

 

 See above for details on implementing wired remote turn-On.  Wire the supplied connector as shown above. 

Additional or replacement connectors are available from Bryston. Part number CO110A11104

6B

SST

2

 

THREE CHANNEL POWER AMPLIFIER

REMOTE POWER TURN-ON

PLUG-IN CONNECTOR

 

Insert  stripped  ends  of  insulated  wires  revealing 

approx. 1/4" of bare, stranded copper wire between 

24 and 12 AWG (.5mm to 2mm dia.)  into open elevator 

style wire clamps & tighten with a slot screw driver. 

Do not over tighten or wires may eventually come 

lose. Maximum tightening torque is 4.5 lb-in (0.5Nm)

TECHNICAL SPECIFICATIONS

PARAMETER 

 

VALUE  UNITS  CONDITIONS

POWER OUTPUT   

300  

Watts 

20-20K Hz into 8 Ohms

 

 

 

500 

Watts 

20-20K Hz into 4 Ohms

SENSITIVITY 

 

1.7 

Vrms 

for 300 Watts out into 8Ω, 29dB gain selected (1Vin=100Wout into 8Ω)

 

 

 

3.4 

Vrms 

for 300 Watts out into 8Ω, 23dB gain selected (2Vin=100Wout into 8Ω)

 

 

 

6.8 

Vrms 

for 300 Watts out into 8Ω, 17dB gain selected (4Vin=100Wout into 8Ω)

INPUT IMPEDANCE 

50K 

Ohms 

balanced input (XLR jack)

 

 

 

10K 

Ohms 

single ended input (RCA jack)

THD+N 

or

 IMD 

 

.005 

20Hz to 20KHz at 300 Watts into 8Ω

 

 

 

.007 

20Hz to 20KHz at 500 Watts into 4Ω

NOISE 

 

 

112 

dB 

Input shorted, 20Hz to 20KHz, 29dB gain, referenced to 300W/8Ω output

 

 

 

115 

dB 

Input shorted, 20Hz to 20KHz, 23dB gain, referenced to 300W/8Ω output

 

 

 

118 

dB 

Input shorted, 20Hz to 20KHz, 23dB gain, referenced to 300W/8Ω output

SLEW RATE 

 

60 

V/µsec 

POWER BANDWIDTH 

<1 to >100K Hz 

DAMPING FACTOR 

500 

 

at 20Hz, ref 8Ω

WEIGHT 

 

 

46.7 (103)  Kg (lbs)  including box and packing (i.e. shipping weight)

POWER CONSUMPTION 

225 

Watts 

at idle

 

 

 

625 

Watts 

1 channel at 300 Watts output into 8Ω

 

 

 

2100 

Watts 

3 channels at 300 Watts output into 8Ω

HEAT DISSIPATION

 

768 

BTU/hr  at idle

 

 

 

1109 

BTU/hr  1 channel driven to 300 Watts output into 8Ω

 

 

 

4097 

BTU/hr  3 channels driven to 300 Watts output into 8Ω

Summary of Contents for 6BSST2

Page 1: ...6BSST2 OWNER S MANUAL ...

Page 2: ...manufacturing defects for twenty 20 years from the original date of manufacture The warranty includes parts and labour Bryston Digital products and cables are warranted for five years from the original date of manufacture The warranty includes parts and labour Bryston products having motorized moving parts excluding motorized volume controls are warranted for three years from the original date of ...

Page 3: ...Power Switch LED Indicators Page 2 REAR PANEL Input Selector Switch Balance Input Connector Single Ended Input Balanced versus Single Ended Input Polarity Switch Page 3 Gain Select Switch Output Binding Posts Channel Module Handles POWER INLET PANEL Master Circuit Breaker A C Power Input Page 4 Remote Power On Off Control Local External Switch External versus Local control Remote Power Turn On Con...

Page 4: ... and if runs are more than 3 meters use at least 12 gauge wire The speaker binding posts will accept wire up to 3 gage in size Bryston can custom build cables for your application A C POWER Before plugging in the power cord be sure your 6BSST2 is specified for the correct a c voltage for your locality The voltage is listed on the data plate located on the Power Inlet Panel see page 4 The 6BSST2 wh...

Page 5: ... persist Any amplifier that is constantly operated into clipping indicates a more powerful amplifier is needed for that application GREEN Indicates channel operation is normal ORANGE Indicates channel is in thermal shutdown The 6BSST2 channel has thermal shutdown circuitry to prevent damage due to overheating Should thermal shutdown occur the channel will mute and the channel LED will turn orange ...

Page 6: ... a quick disconnect option Before inserting a banana plug into the binding post be sure to tighten the post nut to avoid rattling and to provide full insertion of the banana plug Gold plated locking banana plugs are available from Bryston SPADE LUGS provide high contact area and secure fastening Lugs should be gold plated Post diameter is 5 16 8mm lug width 5 8 16 mm Gold plated spade lugs are ava...

Page 7: ...ire the supplied connector as shown above Additional or replacement connectors are available from Bryston Part number CO110A11104 6BSST2 THREE CHANNEL POWER AMPLIFIER REMOTE POWER TURN ON PLUG IN CONNECTOR Insert stripped ends of insulated wires revealing approx 1 4 of bare stranded copper wire between 24and12AWG 5mmto2mmdia intoopenelevator style wire clamps tighten with a slot screw driver Do no...

Page 8: ...EXTERNAL DIMENSIONS FUSE LOCATIONS 300007 1 BRYSTON LIMITED PETERBOROUGH ONTARIO CANADA 2010 07 15 ...

Reviews: