The hold feature freezes the display for later view. LCD
turns on. Press the
button momentarily to toggle the hold feature.
Press the
button for one second or more to toggle between the Standard
6000 counts and 20000 counts High Resolution modes. The analog bar graph full
scale shows
and
accordingly. Last selectionis saved as power up default.
20000 counts High Resolution mode is available to AC/DC Voltage (except VFD
ACV
+Hz
), AC/DC Current and Resistance functions.
Press
turn on. The meter beeps when a new MAX (maximum) or MIN (minimum)
reading is updated. Press the button momentarily to read the Real time, MAX and MIN
readings in sequence. Press the button for 1 second or more to exit MAX/MIN
recording mode. When activated, AutoPowerOff is disabled automatically.
Press
button momentarily to activate CREST (Instantaneous PeakHold) mode
to capture voltage or curre nt signal duration as short as 5ms.
turn on. Press the button momentarily to read the MAX and MIN readings in sequence.
Press the button for 1 second or more to exit CREST mode. AutoPowerOff is
disabled automatically in this mode.
or
input jack when other