18
Electrical Specifications
Accuracy is
±
(% reading number of digits) or otherwise specified, at 23
°
C
±
5
°
C.
Maximum Crest Factor < 2.5 : 1 at full scale & < 5 : 1 at half scale or otherwise
specified, and with frequency spectrum not exceeding the specified frequency
bandwidth for non-sinusoidal waveforms.
DC Voltage
RANGE
Accuracy
600.0V
1.0% + 5d
Input Impedance: 10M
Ω
, 100 pF nominal
AC Voltage (with Digital Low-Pass Filter)
RANGE
Accuracy
50Hz ~ 60Hz
600.0V
1.0% + 5d
Input Impedance: 10M
Ω
, 100 pF nominal
DC+AC Voltage (with Digital Low-Pass Filter) (Models 079 & 078 Only)
RANGE
Accuracy
DC, 50Hz ~ 60Hz
600.0V
1.2% + 7d
Input Impedance: 10M
Ω
, 100 pF nominal
PEAK-rms (ACV & ACA of Models 079, 078 & 076 only)
Response: 80ms to > 90%
Audible Continuity Tester
Audible Threshold: At between 10
Ω
and 250
Ω
Response time: 32ms approx.
Ohm
RANGE
Accuracy
600.0
Ω
, 6.000K
Ω
, 60.00K
Ω
1.0% + 5d
Open Circuit Voltage: 1.0VDC typical