background image

Installation Instructions

GAPAB

PERFECT AIR

t

AIR PURIFIER FOR FAN COILS

SIZES 1620, 2020, AND 2420

NOTE

: Read the entire instruction manual before starting the

install.

TABLE OF CONTENTS

PAGE

INTRODUCTION

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

HOW IT WORKS

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SAFETY CONSIDERATIONS

1

. . . . . . . . . . . . . . . . . . . . . . . . . .

APPLICATION CONSIDERATIONS

2

. . . . . . . . . . . . . . . . . . . .

INSTALLATION

3--6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

START--UP AND OPERATION

7

. . . . . . . . . . . . . . . . . . . . . . . . .

MAINTENANCE

7 -- 8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

TROUBLESHOOTING

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SPECIFICATIONS AND DIMENSIONS

10

. . . . . . . . . . . . . . . . .

WARRANTY

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Congratulations for selecting the Perfect Air

t

Air Purifier for

your home comfort system! The Perfect Air

t

Air Purifier is

proven to remove and kill airborne germs and allergens, including

viruses, bacteria, and mold spores. The Perfect Air

t

Air Purifier

is a cornerstone of Bryant’s Healthy Home Solutions for

providing healthier, cleaner air in your home.

HOW IT WORKS

The Perfect Air

t

Air Purifier provides extremely high filtration

performance while killing captured contaminants, including

viruses, bacteria, and mold spores. The Perfect Air

t

Air Purifier

treats the entire air--stream through a state of the art, three--stage

process, exclusive to Bryant.
In stage one, the particles are electrically charged by a

precision--point ionization array as they enter the Perfect Air

t

Air Purifier.
In stage two, the charged particles are electrically attracted to the

air purification cartridge, which is located within an electric field.
In stage three, captured particles are killed by electrical current

flow and ion bombardment.

The Perfect Air

t

Air Purifier is CSA certified for shock and

electrical fire hazard only.
La Perfect Air

t

Air Purifier certification CSA vise uniquement

les risques de choc electrique et.

A06367

Fig. 1

---

GAPAB Unit

SAFETY CONSIDERATIONS

Improper

installation,

adjustment,

alteration,

service,

maintenance, or use can cause explosion, fire, electrical shock or

other conditions which may cause personal injury or property

damage. Consult a qualified installer, service agency, or your

distributor or branch for information or assistance. The qualified

installer or agency must use factory authorized kits or accessories

when modifying this product. Refer to the individual instructions

packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses and work gloves.

Have a fire extinguisher available.

Read these instructions

thoroughly and follow all warning or cautions attached to the

unit. Consult local building codes and National Electrical Code

(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol

. When you see this symbol on the unit

and in instructions or manuals, be alert to the potential for

personal injury. Understand the signal words DANGER,

WARNING, and CAUTION. These words are used with the

safety--alert symbol.

DANGER identifies the most serious

hazards which

will

result in severe personal injury or death.

WARNING signifies hazards which

could

result in personal

injury or death. CAUTION is used to identify unsafe practices

which

may

result in personal injury or product and property

damage. NOTE is used to highlight suggestions which

will

result

in enhanced installation, reliability, or operation.

Summary of Contents for PERFECT AIR 1620

Page 1: ...CSA certified for shock and electrical fire hazard only La Perfect Airt Air Purifier certification CSA vise uniquement les risques de choc electrique et A06367 Fig 1 GAPAB Unit SAFETY CONSIDERATIONS I...

Page 2: ...recommended and a standard disposable furnace filter should be mounted between the humidifier and the air purifier to trap hard water salt deposits and water droplets Transitions If the return air du...

Page 3: ...Purifier or door can be rotated 180_ to accommodate the cabinet orientation c The location of the Perfect Airt Air Purifier should be readily accessible Enough room should be provided for periodic rep...

Page 4: ...work See Fig 6 h Seal seams with tape or caulking after the Perfect Airt Air Purifier cabinet has been secured ELECTRICAL SHOCK AND HIGH VOLTAGE HAZARD Failure to follow this warning could result in...

Page 5: ...bag With the bypass jumper in place the air purifier will be on at all times when connected to electrical line power see Fig 10 d Attach the quick connect terminals to the fused power connector leads...

Page 6: ...OWER CONNECTION TO L2 FIELD POWER SUPPLY TO L1 FIELD POWER SUPPLY 5 AMP IN LINE FUSES GROUND ATTACH TO FAN COIL GROUND CHASSIS CABLE CONNECTOR TO SECURE POWER CORD TO FAN COIL CABINET A06515 Fig 10 Fa...

Page 7: ...her the TrueSenset dirty filter algorithm or time The installer should use their discretion to select the most appropriate option based on the initial system static pressure Step 3 Maximizing Performa...

Page 8: ...iate protective clothing and gloves when handling parts WARNING Step 6 Slide out the Safety Screen and set aside NOTE Best cleaning tools 5 inch handle paint brush with 2 inch width or greater brush p...

Page 9: ...position Step 3 Confirm that the fan coil blower is operating Step 4 Confirm that 208 230 VAC power is provided Attach power supply connector to the air purifier when the fan coil blower is operating...

Page 10: ...mum Airflow CFM 1350 1800 2000 Efficiency Equivalent to MERV 15 Equivalent to MERV 15 Equivalent to MERV 15 Replacement Cartridge GAPCBBAR1620 GAPCBBAR2020 GAPCBBAR2420 Initial Pressure Drop in w c at...

Page 11: ...ough a registered servicing dealer for credit 4 All work shall be performed during normal working hours LIMITATIONS OF WARRANTIES ALL IMPLIED WARRANTIES AND OR CONDITIONS INCLUDING IMPLIED WARRANTIES...

Page 12: ...change at any time specifications or designs without notice and without incurring obligations EBryant Heating Cooling Systems 7310 W Morris St Indianapolis IN 46231 Printed in U S A Edition Date 02 0...