Bryant LEGACY 564B Owner'S Information Manual Download Page 3

3

Table 1 – Indoor Air Filter Data

Unit Size

Filter Size

024---036

24x24x1 (610x610x25 mm)

042---060

30x30x1 (762x762x25 mm)

If you have difficulty locating your air filter(s) or have questions
concerning proper filter maintenance, contact your dealer for

instructions. When replacing filters, always use the same size and
type of filter that was supplied, originally, by the installer.

UNIT OPERATION HAZARD

Failure to follow this caution may result in property

damage.
Never operate your unit without filters in place. An

accumulation of dust and lint on internal parts of your unit

can cause loss of efficiency.

!

CAUTION

Fans and Fan Motors
Periodically check the condition of fan wheels and housings and

fan--motor shaft bearings. No lubrication of condenser--or
evaporator--fan bearings or motors is required or recommended.
Indoor and Outdoor Coils
Cleaning of the coils should only be done by qualified service
personnel. Contact your dealer for the required annual

maintenance.
Condensate Drain
The drain pan and condensate drain line should be checked and
cleaned at the same time the cooling coils are checked by your

dealer.
Compressor
All compressors are factory shipped with a normal charge of the

correct type of refrigeration grade oil in them and should rarely
require additional oil.
Condenser Fan

PERSONAL

INJURY

AND

UNIT

DAMAGE

HAZARD

Failure to follow this warning could result in personal

injury, death or property damage.
Do not insert sticks, screwdrivers, or any other object into

revolving fan blades.

!

WARNING

The fan must be kept free of all obstructions to ensure proper

cooling. Contact your dealer for any required service.
Electrical Controls and Wiring
Electrical controls are difficult to check without proper

instrumentation. If there are any discrepancies in the operating
cycle, contact your local dealer and request service.
Refrigerant Circuit
The refrigerant circuit is difficult to check for leaks without the

proper equipment. If inadequate cooling is suspected, contact your

local dealer for service.

EXPLOSION AND ENVIRONMENTAL HAZARD

Failure to follow this warning could result in personal

injury, death or property damage.
System under pressure. Relieve pressure and recover all

refrigerant before system repair or final unit disposal. Use

all service ports and open all flow--control devices,

including solenoid valves.

!

WARNING

Unit Panels
After performing any maintenance or service on the unit, be sure
all panels are fastened securely in place to prevent rain from

entering unit cabinet and to prevent disruption of the correct unit
airflow pattern.

REGULAR DEALER MAINTENANCE

In addition to the type of routine maintenance you might be willing
to perform, your unit should be inspected regularly by a properly

trained service technician. An inspection (preferably each year, but

at least every other year) should include the following:

1. Inspection and, if required, cleaning of the indoor coil

condensate drain.

2. Inspection and, if required, cleaning of the evaporator drain

pan.

3. Inspection and cleaning of blower wheel housing and

motor.

4. Inspection of all supply--air and return--air ducts for leaks,

obstructions, and insulation integrity. Any problems found
should be resolved at this time.

5. Inspection of the unit base to ensure that no cracks, gaps,

etc., exist which may cause a hazardous condition.

6. Inspection of the unit casing for signs of deterioration.
7. Inspection of all electrical wiring and components to ensure

proper connection.

8. Inspection for leaks in the refrigerant circuit. Pressure--

check to determine appropriate refrigerant charge.

9. Inspection of compressor oil level by service person to

ensure proper oil level is maintained in the compressor

when it is installed and running.

10. Operational check of the unit to determine working

conditions. Repair or adjustment should be made at this

time.

Your servicing dealer may offer an economical service contract that

covers seasonal inspections. Ask for further details.
Complete service instructions can be found in the unit Installation,

Start--up and Service Instructions.

Warranty Certificate

Your 564B unit has a limited warranty. Be sure to read the
warranty carefully to determine the coverage for your unit.

Before you call for service...

...check for several easily--solved problems.

If insufficient heating or cooling is suspected:

( ) Check for sufficient airflow.
( ) Check the air filter for dirt.
( ) Check for blocked return--air or supply--air grilles. Be sure they

are open and unobstructed. If these checks do not reveal the cause,

call your servicing dealer.

If your unit is not operating at all, check the following list for

easy solutions:

(

) Check to be sure that your thermostat temperature selector is

set below the indoor temperature during the cooling season. Be