2
Color
Mode
Suggested Use
Green
Intermittent
Select this mode when you are away from the house for a few days, or when
you deem the inside air is too dry in heating season or too humid in cooling
season. In this mode the unit is OFF for 40 minutes per hour and ventilates at
minimum speed the remaining 20 minutes of the hour.
Yellow
Minimum Speed
Ventilation
For normal daily operation
Red
Maximum Speed
Ventilation
For excess pollutants and humidity
(Parties, odors, smoke, etc.)
INSTALLATION
Step 1—
Cut a 2 3/8 in. high by 1 3/8 in. wide hole in the wall.
See Fig. 1.
Step 2—
Temporarily place the switch in the hole to mark the
correct locations for the 2 wall anchors.
Step 3—
Remove the switch, drill the 2 wall--anchor holes and
insert the wall anchors into the wall.
Step 4—
Using Fig. 2 as a guide, connect the electrical wiring.
Step 5—
Finish mounting KVBCN0101BLT wall control. Plug
the unit in and test the wall control operation.
1 3/8 in.
2 3/8 in.
A05294
Fig. 1 -- Wall Control Installation
NO C NC I OC OL Y R G B
B
G
OC
KVBCN0101BLT Control
REAR VIEW
G B
Y
A05295
Fig. 2 -- Wall Control Wiring
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
E
Bryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231
Printed in U.S.A.
Edition Date: 12/05
Replaces: NEW
Catalog No. AG---KVBCN---B01