Bryant HUM Series Homeowner'S Manual Download Page 3

 

—3—

 

Fig. 4—Saddle Valve

Fig. 5

 

 

On a Model HUMBBLBP or Model 

HUMBBLFP humidifier, loosen the 
thumbscrew that holds the distributor 
cover to the top of the cabinet. Lift up the 
distributor cover slightly to make certain 
that water is flowing from the solenoid 
valve into the distributor pan. Do not lift 
the cover off the cabinet more than 1 in. 
when water is flowing. (See Fig. 6 or 7 
according to the model you own.)

 

Fig. 6—

Model HUMBBLBP2018-A--

 

 

On a Model HUMBBSBP humidifier, 

gently pull the latch that secures the 
access door. Remove the door. Check to 
see if water is flowing from the solenoid 
valve into the evaporator pad. (See Fig. 8.)

 

 

On a Model HUMBBSFP humidifier, 

open the side door or the front cover. If the 
front cover is opened, hold the pad assem-

bly in place. Check to see if water is flow-
ing from the solenoid valve into the 
distributor pan. (See Fig. 9.)

 

 

On a Model HUMBBWTR unit, look 

through the window on front of the unit to 
see that the evaporator pad is rotating and 
water is flowing. (See Fig. 10.)

The Model HUMBBWTR is controlled 
by a float valve. Turning off the furnace 
will not affect the water flow until float 
level is achieved. (See Fig. 11.)

 

Fig. 7—

Model HUMBBLFP1025-A--

Fig. 8—

Model HUMBBSBP2017-A--

Fig. 9—

Model HUMBBSFP1016-A--

 

4. Turn off the furnace. When the 

blower stops, look into the humidi-
fier to make sure the water is not 
flowing into the unit.

5. Replace the cover assembly and 

fasten securely.

6. Now, turn the furnace on and set

the thermostat for desired room 
temperature.

 

SHUTDOWN PROCEDURES

 

To shut down your humidifier, close the 
saddle valve on the water line. Then turn 
off the humidistat. When set to the OFF 
position, the humidistat shuts off the 
electrical power to the solenoid valve on 
the humidifier.

 

NOTE:

 

 If your home comfort system in-

cludes cooling, be sure the water supply 
to your humidifier is 

 

turned off

 

 during 

the cooling season. Close the damper 
located in the bypass duct if one is 
installed. If your humidifier is a Model 
HUMBBWTR, drain and clean the water 
pan as described in cleaning procedures.

 

PERFORMING ROUTINE 
MAINTENANCE

 

With the proper maintenance and care, 
your humidifier will operate economi-
cally and dependably. Maintenance can 
be accomplished easily by referring to 
the following directions. However,
before performing any maintenance, 
consider these important safety 
precautions:

 

 

DISCONNECT ALL ELECTRI-

CAL POWER TO THE HUMIDIFIER 
AND FURNACE BEFORE PER-
FORMING ANY SERVICE OR 
MAINTENANCE TO AVOID PER-
SONAL INJURY.

 

Fig. 10—

Model HUMBBWTR2019-A--

 

NOTE: 

 

THERE MAY BE MORE 

THAN 1 ELECTRICAL DISCON-
NECT SWITCH.

 

 

ALTHOUGH SPECIAL CARE HAS 

BEEN TAKEN TO MINIMIZE SHARP 
EDGES IN THE CONSTRUCTION OF 
YOUR HUMIDIFIER, BE EXTREME-
LY CAREFUL WHEN HANDLING 
PARTS OR REACHING INTO THE 
UNIT TO AVOID PERSONAL INJURY.

Your humidifier has been designed for 
easy disassembly to simplify cleaning 
and servicing. Your unit must be kept 
clean to maintain its efficiency.

HUMIDISTAT

SOLENOID VALVE

DISTRIBUTOR COVER

DISTRIBUTOR PAN

EVAPORATOR PAD

CABINET

BOTTOM ACCESS

PANEL

SOLENOID VALVE

DISTRIBUTOR COVER

DISTRIBUTOR PAN

EVAPORATOR PAD

CABINET

BOTTOM ACCESS PANEL

INLET

CABINET

DUCT HOUSING

RECTIFIER

DRAIN

SIDE ACCESS DOOR

EVAPORATOR PAD

DISTRIBUTOR PAN

SOLENOID VALVE

CABINET

FRONT COVER

SCREWS (4)

PAD ASSEMBLY

SIDE ACCESS DOOR

BEARING RETAINER

CABINET

PAD

PAN

 