background image

4

The off--delay is set by moving a jumper on the control. The
Wiring Diagram located on the inside of the blower door shows the

various delay combinations. Refer to Fig. 2 for location of the
control.
If you are unsure how to set the Off--delay Control, contact a

Qualified Service Agency.
Set the room thermostat slightly above room temperature. This will

automatically signal the furnace to start. The inducer motor will
start, and the hot surface igniter will have an orange glow. After

about 32 seconds (from the call for heat at the thermostat), the gas

valve permits gas to flow to the main burners where it is ignited.
When the flame is firmly established, the igniter shuts off. Hot

flames begin to warm the furnace’s heat exchanger. After a time
delay of 30 seconds, the furnace blower is switched on.

NOTE

: If the main burners fail to ignite, the furnace control

system will go through 3 more ignition cycles. Then, if burners fail
to ignite, the system will lockout. If lockout occurs, or the blower
doesn’t come on, shut down your furnace and call a Qualified
Service Agency for service.

Pressure Switch

The furnace is equipped with one or more pressure switches to shut
down the furnace under various flue conditions. The switches are

connected to the furnace by factory supplied tubing.

Operating Your Furnace

Keep the blower access door and all access panels in place except

for inspection or maintenance.
Before starting your furnace be sure you read and understand all of
the procedures in this manual. Check to make sure the furnace filter

is clean and correctly installed.

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury

or death.
Provisions for combustion and ventilation air must be

provided for in accordance with installation instructions

supplied with furnace.

!

WARNING

Starting The Furnace

See Fig. 4 for an illustration of the gas control valve.

1. Turn the thermostat to its lowest temperature setting or to

OFF if equipped with a System Select Switch.

2. Turn OFF all electric power to the furnace at the disconnect

switch or circuit breaker.

3. Remove the burner compartment door by removing the

two(2) screws securing the door in front and lifting the door
up and outwards. Removing the door will expose the gas

control valve knob.

4. Turn the gas control valve to the OFF position. See Fig. 3.
5. Wait five (5) minutes to clear out any gas. If you then smell

gas, STOP! Follow the safety information on the cover of
this manual. If you do not smell gas, go to the next step.

6. Turn the gas control valve to the ON position. See Fig. 3.
7. Reinstall all doors.
8. Turn ON all electrical power to the furnace.
9. Set the thermostat to the desired temperature and the System

Select Switch to HEAT.

The furnace will activate an igniter which lights the main burners.

Turning Off The Furnace

Set the thermostat to the lowest temperature setting or set System

Select Switch to OFF, if so equipped.

Should overheating occur or the gas control valve fail to shut

off, shut off the manual equipment shutoff valve to the furnace

before shutting off the electrical supply.

Extended Shutdown

1. Set thermostat to lowest temperature setting or set thermo-

stat System Select Switch to OFF, if so equipped.

2. Turn Manual Equipment Shutoff Valve for furnace to OFF

position (at right angle or 90

_

to gas line).

3. Remove the burner compartment door by removing the two

(2) screws securing the door in front and lifting the door up
and outwards. Removing the door will expose the gas con-
trol valve knob.

4. Turn OFF electric power to the furnace at the disconnect

switch or circuit breaker. (May be left ON for set--back type

thermostat with batteries, provided thermostat has system
select switch placed in the OFF position.)

5. Turn the the gas control valve to the OFF position. See Fig.

3.

6. Reinstall all doors.

Propane Gas Model Furnaces

FIRE OR EXPLOSION HAZARD

Failure to follow this warning could result in property damage,

personal injury or death.
Propane gas is heavier than air. Leaking gas could settle in low

areas such as crawl space. If you suspect the presence of gas,

follow the instructions on the cover of this manual.

!

WARNING

If your propane gas furnace is installed in an excavated or low

lying area, we recommend that you contact your propane gas

supplier about installing a warning device that would alert you of a
gas leak.

Frozen Water Pipe Hazard

PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in property damage
Furnace may shut down. Do not leave your home unattended

for long periods during freezing weather without turning off

water supply and draining water pipes or otherwise protecting

against the risk of frozen pipes.

CAUTION

!

Your furnace is designed solely to provide a safe and comfortable
living environment. The furnace is NOT designed to ensure that

water pipes will not freeze. It is equipped with several safety
devices that are designed to turn the furnace off and prevent it from

restarting in the event of various potentially unsafe conditions.
If your furnace remains off for an extended time, the pipes in your

home could freeze and burst, resulting in water damage. If the

structure will be unattended during cold weather, you should take
these precautions.

1. Turn off the water supply to the structure and drain the wa-

ter lines if possible and add an antifreeze for potable water

to drain traps and toilet tanks. Open faucets in appropriate
areas.

--or--

359AA

V

Summary of Contents for HIGH EFFICIENCY GAS FURNACE 359AAV

Page 1: ...cy should be contacted to inspect the furnace and to replace all gas controls control system parts electrical parts that have been wet or the furnace if deemed necessary CERTIFIED DE S I GN C E R T I...

Page 2: ...8 mm from the draft hood open ing Reference Fig 1 which shows a water heater draft hood Typical Gas Water Heater Draft Hood Vent Pipe Match A07688 Fig 1 Water Heater Draft Hood a Match flame pulls tow...

Page 3: ...e on off with the furnace on the heating speed unless a call for cooling is initiated Blower speed will correspond to the mode of operation of the furnace If the Fan Switch is positioned to ON the blo...

Page 4: ...electrical power to the furnace 9 Set the thermostat to the desired temperature and the System Select Switch to HEAT The furnace will activate an igniter which lights the main burners Turning Off The...

Page 5: ...should be inspected at least monthly and cleaned or replaced as required There are many types of filters that are commonly used Washable filters constructed of aluminum mesh foam or reinforced fibers...

Page 6: ...o side A07691 Fig 5 Bottom Mounted Filter Inside Furnace External Filter Rack A plastic end cap is inserted in the filter rack after the filter is installed The end cap keeps air from escaping around...

Page 7: ...0 x 635 0 1 Req 14 x 25 355 6 x 635 0 1 Req 1100 1300 14 x 25 355 6 x 635 0 2 Req 14 x 25 355 6 x 635 0 1 Req 1300 1500 16 x 18 406 4 x 457 2 2 Req 16 x 18 406 4 x 457 2 1 Req 1500 1700 20 x 25 508 0...

Page 8: ...Systems TO OBTAIN INFORMATION ON PARTS Consult your installing dealer or classified section of your local telephone directory under the Heating Equipment or Air Conditioning Contractors Systems headin...

Reviews: