SPECIFICATIONS

Heating Capacity and Efficiency

030040

042060

048080

048100

066120

Input

High Heat

(BTUH)

40,000

60,000

80,000

100,000

120,000

Low Heat

(BTUH)

26,000

39,000

52,000

65,000

78,000

Output

High Heat

(BTUH)

39,000

58,000

78,000

98,000

117,000

Low Heat

(BTUH)

25,000

38,000

50,000

63,000

76,000

Efficiency

AFUE % (ICS)

96.5

96.3

96.2

96.5

96.5

Certified Temperature

Rise Range ºF (ºC)

High Heat

40 - 70

(21-38)

35 - 65

(19-36)

40 - 70

(21-38)

45 - 75

(25-41)

45 - 75

(25-41)

Low Heat

30 - 60

(17-33)

30 - 60

(17-33)

30 - 60

(17-33)

30 - 60

(17-33)

30 - 60

(17-33)

Airflow Capacity and Blower Data

030040

042060

048080

048100

066120

Certified External Static

Pressure (in. w.c.)

Heating

0.10

0.12

0.15

0.20

0.20

Cooling

0.5

0.5

0.5

0.5

0.5

Airflow Delivery

@ Rated ESP (CFM)

High Heat

815

1135

1510

2035

2375

Low Heat

660

860

860

1530

1675

Cooling

905

1475

1610

1805

2115

Cooling Capacity (tons)

@ 400, 350 CFM/ton

400 CFM/ton

2

3.5

4

4.5

5

350 CFM/ton

2.5

4

4.5

5

6

Direct-Drive Motor Type

Electronically Commutated Motor (ECM)

Direct-Drive Motor HP

1/2

3/4

3/4

1

1

Motor Full Load Amps

6.8

8.4

8.4

10.9

10.9

RPM Range

600 - 1200

Speed Selections

Variable (PWM)

Blower Wheel Dia x Width

in.

11x7

11x8

11x8

11x10

11 x 11

Air Filtration System

Factory Supplied Media Cabinet

Field Supplied Filter

Filter Used for Certified Watt Data

KGAWF1606UFR KGAWF1306UFR

KGAWF1406UFR KGAWF1506UFR

KGAWF1506UFR

Electrical Data

030040

042060

048080

048100

066120

Input Voltage

Volts-Hertz-Phase

115-60-1

Operating Voltage Range

Min-Max

104-127

Maximum Input Amps

Amps

8.2

9.8

9.8

12.3

12.3

Unit Ampacity

Amps

11.0

13.0

13.0

16.1

16.1

Minimum Wire Size

AWG

14

14

14

12

12

Maximum Wire Length

@ Minimum Wire Size

Feet

33

28

28

35

35

(M)

(10.1)

(8.5)

(8.5)

(10.7)

(10.7)

Maximum Fuse/Ckt Bkr

(Time-Delay Type Recommended)

Amps

15

15

15

20

20

Transformer Capacity (24vac output)

40 VA

External Control Power

Available

Heating

24.3 VA

Cooling

34.6 VA

Controls

030040

042060

048080

048100

066120

Gas Connection Size

1/2” - NPT

Burners (Monoport)

2

3

4

5

6

Gas Valve (Redundant)

Manufacturer

White Rogers™

Minimum Inlet Gas

pressure (in. W.C.)

4.5

Maximum Inlet Gas

pressure (in. W.C.)

13.6

Gas Conversion Kit - Natural to Propane

KGANP5201VSP

Gas Conversion Kit - Propane to Natural

KGAPN4401VSP

Manufactured (Mobile) Home Kit

not approved for MH use

Ignition Device

Silicon Nitride

Limit Control

165

180

170

160

160

Heating Blower Control (Heating Off-Delay)

Adjustable: 90, 120, 150, 180 seconds

Cooling Blower Control (Time Delay Relay)

90 seconds

Communication System

Evolution (non-zoning)

Thermostat Connections

W2, Y1, DHUM, G, COM 24V, W/W1, Y/Y2, R

Accessory Connections

EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)

Summary of Contents for EVOLUTION 986TA

Page 1: ... Plus technology allows control of continuous fan speed from a compatible thermostat S External Media Filter Cabinet included S 4 way multipoise design for upflow downflow or horizontal installations with unique vent elbow and optional through the cabinet downflow venting capability S Variable Speed blower motor two speed inducer motor and two stage gas valve S Self diagnostics and extended diagno...

Page 2: ...Supplied Media Cabinet Field Supplied Filter Filter Used for Certified Watt Data KGAWF1606UFR KGAWF1306UFR KGAWF1406UFR KGAWF1506UFR KGAWF1506UFR Electrical Data 030040 042060 048080 048100 066120 Input Voltage Volts Hertz Phase 115 60 1 Operating Voltage Range Min Max 104 127 Maximum Input Amps Amps 8 2 9 8 9 8 12 3 12 3 Unit Ampacity Amps 11 0 13 0 13 0 16 1 16 1 Minimum Wire Size AWG 14 14 14 1...

Page 3: ... 66 2200 CFM 0 5 ESP 040 40 000 BTU 060 60 000 BTU 080 80 000 BTU 100 100 000 BTU 120 120 000 BTU Not all familes have these models A11163 FURNACE COMPONENTS RATING PLATE NOT SHOWN LOCATED ON BLOWER DOOR GAS VALVE MAIN LIMIT SWITCH BEHIND GAS VALVE REPRESENTATIVE DRAWING ONLY SOME MODELS MAY VARY IN APPEARANCE ELECTRICAL JUNCTION BOX IF REQUIRED LOCATION MAY VARY MEDIA CABINET OPERATING INSTRUCTIO...

Page 4: ... Gas Orifice Kit 56 LP KGAHA0850P56 X X X X X Gas Orifice Kit 1 25mm LP KGAHA5750125 X X X X X Gas Orifice Kit 1 30mm LP KGAHA5750130 X X X X X Indoor Air Quality Bryant Perfect Air Purifier 16x25 406x635 mm GAPAAXBB1625 A08 X X X X X Bryant Perfect Air Purifier 20x25 508x635 mm GAPAAXBB2025 A08 X X X X X Bryant Perfect Air Purifier Repl Filter 16x25 406x635 mm GAPABBCAR1625 A05 X X X X X Bryant P...

Page 5: ...520 435 OFF ON OFF 780 725 660 615 540 OFF ON ON 975 925 875 835 785 750 690 655 610 570 ON OFF OFF 1160 1120 1090 1045 1010 970 920 885 840 800 ON OFF ON 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 ON ON OFF 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 ON ON ON 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 Maximum Cooling Airflow2 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 H...

Page 6: ...1035 970 905 845 ON OFF ON 1615 1550 1500 1435 1370 1325 1265 1215 1160 1110 ON ON OFF 2010 1960 1910 1850 1800 1750 1690 1645 1565 1480 ON ON ON note 7 2375 2300 2205 2115 2010 1890 1750 1645 1550 Maximum Cooling Airflow2 note 7 2375 2300 2205 2115 2010 1890 1750 1645 1550 High Heat Airflow3 note 7 2375 2300 2205 2115 2010 1890 1750 1645 1550 Low Heat Airflow3 1735 1675 1625 1560 1500 1455 1395 1...

Page 7: ...02 61 6 224 68 3 100 000 NA 17 5 2 94 28 7 205 62 5 229 69 8 120 000 NA NA NA 83 25 3 217 66 1 Not all families have these models Note See notes at end of venting tables Note Table 3 for altitudes over 4500 ft 1370 M Table 2 Deductions from Maximum Equivalent Vent Length Ft M Pipe Diameter in 1 1 2 2 2 1 2 3 4 Mitered 90º Elbow 8 2 4 8 2 4 8 2 4 NA NA NA NA Medium Radius 90º Elbow 5 1 5 5 1 5 5 1 ...

Page 8: ... 2 1 82 25 0 152 46 3 168 51 2 NA 80 000 NA 35 10 7 111 33 8 148 45 1 156 47 5 100 000 NA NA 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 9001 to 10 000 2743 to 3048 40 000 5 1 5 110 33 5 115 35 1 NA NA 60 000 NA 76 23 2 142 43 3 156 47 5 NA 80 000 NA 31 9 4 103 31 4 137 41 8 142 43 3 100 000 NA NA 62 18 9 147 44 8 157 47 9 120 000 NA NA NA 51 15 5 153 46 6 Not all families have the...

Page 9: ... 1 21 3 53 3 53 9 44 8 0 20 Ft 20 0 32 0 30 0 22 0 11 0 20 0 70 0 104 0 87 0 67 0 20 0 70 0 124 0 104 0 82 0 M 6 1 9 8 9 1 6 7 3 4 6 1 21 3 31 7 26 5 20 4 6 1 21 3 37 8 31 7 25 0 20 30 Ft 20 0 17 0 14 0 6 0 0 0 20 0 70 0 71 0 57 0 40 0 20 0 70 0 86 0 71 0 52 0 M 6 1 5 2 4 3 1 8 0 0 6 1 21 3 21 6 17 4 12 2 6 1 21 3 26 2 21 6 15 8 40 40 Ft 15 0 7 0 5 0 0 0 0 0 20 0 61 0 52 0 40 0 24 0 20 0 70 0 64 0...

Page 10: ...of heat exchangers motors and controls 60 80 27 C 16 C SUPPLY AIR A10490 MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service 24 in 610 mm All Sides of Supply Plenum 1 in 25 mm Sides 0 0 mm Vent 0 0 mm Top of Furnace 1 in 25 mm Recommended COMBUSTION AIR PIPE FOR NON DIRECT 1 PIPE VENT A...

Page 11: ...sed Coil Assembly or Coil Box 22 1 8 562 0 19 482 6 23 3 4 603 3 20 3 8 517 5 1 The plenum should be constructed 1 4 in 6 mm smaller in width and depth than the plenum dimensions shown above Concentric Vent Kit A93086 A concentric vent kit allows vent and combustion air pipes to terminate through a single exit in a roof or side wall One pipe runs inside the other allowing venting through the inner...

Page 12: ... 115 V FIELD SUPPLIED DISCONNECT AUXILIARY J BOX 24 V TERMINAL BLOCK THREE WIRE HEATING ONLY FIVE WIRE NOTE 1 NOTE 2 FIELD SUPPLIED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE C O N T R O L R G COM W C R G Y GND GND FIELD 24 V WIRING FIELD 115 208 230 460 V WIRING FACTORY 24 V WIRING FACTORY 115 V WIRING 208 230 OR 460 V THREE PHASE 208 230 V SINGLE PHASE BLOWER DOOR SWITCH WHT BLK WHT BLK NOTES C...

Page 13: ... B OUTLET WIDTH A 22 558 3 14 13 16 376 3 35 889 0 5 8 15 8 1 5 16 33 3 29 1 2 749 3 19 1 8 485 8 VENT AIR INTAKE AIR FLOW AIR FLOW SIDE INLET SIDE INLET CONDENSATE DRAIN TRAP LOCATION THERMOSTAT ENTRY 22 2 7 8 PART NUMBER SD5024 4 NEXT SHEET NONE 7 8 22 2 POWER CONN AIR FLOW NOTE Doors may vary by model a For 800 CFM 16 in 406 mm round or 14 1 2 x 12 in 368 x 305 mm rectangle b For 1200 CFM 20 in...

Page 14: ...n Primary Heat Exchangers Primary heat exchangers shall be 3 Pass corrosion resistant aluminized steel of fold and crimp sectional design and applied operating under negative pressure Secondary Heat Exchangers Secondary heat exchangers shall be of a stainless steel flow through of fin and tube design and applied operating under negative pressure Controls Controls shall include a micro processor ba...

Reviews: