26
COMBINATION RATINGS CONTINUED
AHRI Ref.
No.
Outdoor Model
Number
Indoor Coil
Model Number
Furnace Model
Capacity
EER
SEER
ID CFM
High
Low
High
Low
3747403
187BNA060****A
CNPV*6024A**+UI
355(A,C)AV060120
58,000
47,000
12.6
16.0
1680
1360
3747511
187BNA060****A
CNPV*6024A**+UI
355BAV060100
57,500
47,000
12.3
15.5
1660
1395
3747508
187BNA060****A
CNPV*6024A**+UI
355BAV060120
58,000
47,000
12.6
16.0
1680
1360
3747440
187BNA060****A
CNPV*6124A**
313*AV060110
59,500
48,500
13.2
16.5
1710
1435
3747411
187BNA060****A
CNPV*6124A**
313*AV060135
59,000
47,500
13.1
16.5
1675
1290
3747450
187BNA060****A
CNPV*6124A**
353(A,B)AV060100
59,000
47,500
13.1
16.5
1650
1285
3747451
187BNA060****A
CNPV*6124A**
353(A,B)AV060120
58,500
47,000
13.0
16.5
1660
1300
3747465
187BNA060****A
CNPV*6124A**
368RAN060120
59,500
47,500
12.9
16.5
1735
1350
3747464
187BNA060****A
CNPV*6124A**
374RAN060120
59,000
47,500
12.5
16.0
1740
1355
3747407
187BNA060****A
CNPV*6124A**+TDR
59,500
47,500
12.8
15.0
1750
1400
3747439
187BNA060****A
CNPV*6124A**+UI
315(A,J)AV060110
59,000
48,000
13.0
16.0
1695
1355
3747409
187BNA060****A
CNPV*6124A**+UI
315(A,J)AV066135
59,500
48,000
13.2
16.5
1685
1355
3747410
187BNA060****A
CNPV*6124A**+UI
315(A,J)AV066155
59,500
48,000
13.3
16.5
1705
1365
3747438
187BNA060****A
CNPV*6124A**+UI
355(A,C)AV060100
58,500
47,500
12.5
15.5
1660
1395
3747408
187BNA060****A
CNPV*6124A**+UI
355(A,C)AV060120
59,000
47,500
12.8
16.0
1680
1360
3747510
187BNA060****A
CNPV*6124A**+UI
355BAV060100
58,500
47,500
12.5
15.5
1660
1395
3747509
187BNA060****A
CNPV*6124A**+UI
355BAV060120
59,000
47,500
12.8
16.0
1680
1360
3747434
187BNA060****A
CSPH*6012A**
313*AV060110
59,000
47,000
13.1
16.5
1710
1270
3747435
187BNA060****A
CSPH*6012A**
313*AV060135
58,500
47,000
13.0
16.5
1675
1275
3747456
187BNA060****A
CSPH*6012A**
353(A,B)AV060100
58,500
47,000
13.1
16.5
1650
1270
3747457
187BNA060****A
CSPH*6012A**
353(A,B)AV060120
59,000
47,000
13.2
16.5
1660
1290
3747466
187BNA060****A
CSPH*6012A**
374RAN060120
58,500
47,500
12.4
16.0
1740
1355
3747427
187BNA060****A
CSPH*6012A**+TDR
59,000
47,000
12.7
15.0
1750
1400
3747431
187BNA060****A
CSPH*6012A**+UI
315(A,J)AV060110
58,500
47,500
12.9
16.0
1695
1355
3747432
187BNA060****A
CSPH*6012A**+UI
315(A,J)AV066135
59,000
47,500
13.1
16.5
1685
1355
3747433
187BNA060****A
CSPH*6012A**+UI
315(A,J)AV066155
59,000
47,500
13.2
16.5
1705
1365
3747428
187BNA060****A
CSPH*6012A**+UI
355(A,C)AV060080
58,000
47,000
12.2
15.5
1730
1310
3747429
187BNA060****A
CSPH*6012A**+UI
355(A,C)AV060100
58,000
47,500
12.4
15.5
1660
1395
3747430
187BNA060****A
CSPH*6012A**+UI
355(A,C)AV060120
58,500
47,500
12.7
16.0
1680
1360
3747436
187BNA060****A
FEUI
59,500
48,000
13.4
17.0
1750
1400
3747437
187BNA060****A
FV4CNB006
59,500
48,000
13.4
16.5
1750
1400
{
Tested combination
EER
— Energy Efficiency Ratio
SEER
— Seasonal Energy Efficiency Ratio
TDR —
Time---Delay Relay. In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause
degradation in performance. Use either the accessory Time---Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces
are
equipped with TDR.
TXV
— Thermostatic Expansion Valve
UI
—
User Interface
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations
are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are affected.
187B
/
180B