5
—
F
ig. 4
— Ba
se Un
it Dim
e
ns
ions
NO
T
E
S
:
1
.
F
o
r
out
doo
r u
s
e o
n
ly
.
2
.
W
e
ig
hts show
n
a
re
f
o
r
5
81A
(l
o
w
hea
t) uni
t
w
it
h ma
n
u
al
2
5
%
o
u
tdo
o
r ai
r o
p
ti
on
, a
lum
in
u
m
coi
ls
,
an
d s
tand
ar
d
d
ri
v
e. F
o
r w
e
ight
s of o
p
ti
o
nal
e
qui
p
m
e
n
t co
nsu
lt pr
odu
ct
d
a
ta
boo
k.
3.
D
o
n
o
t l
o
c
a
te
ad
ja
ce
n
t un
it
s
w
it
h
f
lu
e
di
s
c
h
ar
g
e
f
a
c
ing
e
c
ono
mi
z
e
r i
n
le
t.
M
in C
le
aranc
es t
o
be
:
R
ig
ht S
ide
:
6
′
-0
″
[1
829
] C
o
nde
nse
r A
ir
Le
ft
S
ide
:
1
0
′
-0
″
[3
048
] Ou
tside
A
ir
F
ront S
id
e
:
3
′
-0
″
[9
15]
S
e
rv
ic
e
6
′
-0
″
[1
829
] C
o
nde
nse
r A
ir
8
′
-0
″
[2
4
3
8
] Co
il
Re
m
o
v
a
l
Re
a
r S
id
e
:
6
′
-0
″
[1
829
] C
o
nde
nse
r A
ir
6
′
-6
″
[1
981
] E
c
o
nom
iz
er
R
e
m
o
v
a
l
To
p
:
6
′
-0
″
[1
829
] C
o
nde
nse
r F
a
n
Bo
tt
o
m
:
1
′
-2
″
[3
56]
C
o
m
b
ust
ib
le S
u
rf
a
c
e
(W
it
h
o
u
t Cu
rb
)
F
lue Out
le
t:
4
′
-0
″
[1
219
] C
o
mb
u
s
ti
b
le
S
u
rf
ace
s
/
Utility M
e
te
rs
/Re
g
u
la
to
rs/
Re
lie
fs
4
.
F
o
r sm
al
le
r ser
v
ic
e an
d op
erati
o
na
l cl
e
a
ran
c
es co
nta
c
t
B
ry
a
n
t A
p
p
lic
ati
o
n E
n
gi
ne
er
in
g D
e
par
tm
en
t.
5
.
D
o
w
n
sho
t duct
s
d
e
si
g
ned
t
o
be att
a
ch
ed to
a
ccesso
ry
roof
cu
rb
o
n
ly
. If uni
t
is
m
o
u
n
te
d si
de
s
upp
ly
, i
t i
s
re
com
-
m
end
ed
t
he d
u
cts mu
st be su
pp
or
ted
by cros
s brace
s
as
d
one
on
acce
ssor
y
ro
of c
u
rb
.
6
.
Dim
e
n
sio
n
s in
[
] a
re
in
m
illim
e
te
rs.
7
.
W
ith the
e
x
cep
ti
on of cl
eara
n
ce f
o
r
th
e
c
ond
ens
er coi
l
a
nd t
he d
a
m
per
/pow
e
r e
x
ha
ust a
s
stat
ed i
n
N
o
te
#3,
a
re
mov
a
b
le
f
e
nce
or
bar
ri
cad
e
r
e
q
u
ir
e
s
no
cl
ea
rance.
8.
D
im
en
s
ion
s
ar
e
f
rom
ou
ts
id
e
of
b
a
s
e
r
a
il.
A
llo
w
0
5
/
16
″
[8
]
o
n
e
a
ch
si
de
fo
r to
p cov
e
r d
ri
p
edg
e
.
U
N
IT SI
ZE
58
1A
OP
E
R
A
T
IN
G
WEI
G
HT
(Low H
eat
Ga
s)
UNIT
HE
IGHT
C
E
N
T
E
R OF
GRA
V
IT
Y
L
O
CA
T
ION
CO
RNER WEIGHT
lb
[k
g
]
WX
Y
Z
lb
[kg
]
in
. [m
m
]
in
. [
m
m
]
in
. [m
m
]
in
.
[m
m
]
A
B
C
D
21
0
22
24
[10
0
8
]
58
1
/
8
[1
476
]
64
1
/
2
[163
8]
33
1
/
2
[8
51
]
30
[76
2
]
610
[277
]
75
1
[34
1
]
38
7
[1
76]
476
[216
]
24
0
22
72
[10
3
0
]
58
1
/
8
[1
476
]
64
[162
6]
34
[8
64
]
30
[76
2
]
625
[283
]
76
0
[34
5
]
40
0
[1
81]
487
[221
]
30
0
25
26
[11
4
6
]
70
1
/
8
[1
781
]
68
[172
7]
34
1
/
2
[8
76
]
34
1
/
2
[87
6
]
662
[300
]
85
9
[39
0
]
43
4
[1
98]
571
[260
]
Summary of Contents for DURAPAC PLUS 581A
Page 3: ...3 Fig 1 Roof Curb Details...
Page 44: ...44 Fig 40 Low Voltage Control Schematic...
Page 45: ...45 Fig 41 Power Schematic...
Page 46: ...46 Fig 42 Component Arrangement...
Page 52: ...Copyright 2005 Bryant Heating Cooling Systems Printed in U S A CATALOG NO 04 53581005 01...
Page 53: ......
Page 54: ......
Page 55: ......